The frequency dependence of ultrasonic velocity and the anisotropy of dispersion in both freshly excised and formalin-fixed myocardium
- PMID: 16616606
- DOI: 10.1016/j.ultrasmedbio.2005.12.002
The frequency dependence of ultrasonic velocity and the anisotropy of dispersion in both freshly excised and formalin-fixed myocardium
Abstract
The objectives of this study were to measure the frequency dependence of the ultrasonic velocity in myocardium and to quantify the frequency dependence of phase velocity as a function of the insonification angle relative to the predominant direction of the myofibers. Broadband phase spectroscopy data were acquired, spanning a frequency range of 3 to 8 MHz. Measurements were made on 36 tissue specimens cored from 12 freshly excised lamb hearts and were repeated after fixation with formalin. Measured phase velocities were found to be well characterized by a logarithmic fit. For freshly excised myocardium, the dispersion over the 3 to 8 MHz bandwidth was dependent on the direction of insonification, ranging from 1.2 m/s change for perpendicular insonification (across the myofibers) to 3.7 m/s for parallel insonification (along the myofibers). The effects of formalin-fixation resulted in a significant increase in dispersion for perpendicular insonification, but did not appreciably alter the dispersion for parallel insonification.
Similar articles
-
Anisotropy of the backscatter coefficient of formalin-fixed ovine myocardium.J Acoust Soc Am. 2007 Jul;122(1):581-6. doi: 10.1121/1.2737747. J Acoust Soc Am. 2007. PMID: 17614514
-
Estimating myocardial attenuation from M-mode ultrasonic backscatter.Ultrasound Med Biol. 2005 Apr;31(4):477-84. doi: 10.1016/j.ultrasmedbio.2004.12.024. Ultrasound Med Biol. 2005. PMID: 15831326
-
Measurements of the anisotropy of ultrasonic velocity in freshly excised and formalin-fixed myocardial tissue.J Acoust Soc Am. 2005 Jul;118(1):505-13. doi: 10.1121/1.1925947. J Acoust Soc Am. 2005. PMID: 16119369 Free PMC article.
-
Characterization of anisotropic myocardial backscatter using spectral slope, intercept and midband fit parameters.Ultrason Imaging. 2007 Apr;29(2):122-34. doi: 10.1177/016173460702900204. Ultrason Imaging. 2007. PMID: 17679326
-
Measurements of the anisotropy of ultrasonic attenuation in freshly excised myocardium.J Acoust Soc Am. 2006 May;119(5 Pt 1):3130-9. doi: 10.1121/1.2188333. J Acoust Soc Am. 2006. PMID: 16708967
Cited by
-
Echocardiographic tissue characterization demonstrates differences in the left and right sides of the ventricular septum.Ultrasound Med Biol. 2010 Oct;36(10):1653-61. doi: 10.1016/j.ultrasmedbio.2010.07.007. Ultrasound Med Biol. 2010. PMID: 20800946 Free PMC article.
-
Power laws prevail in medical ultrasound.Phys Med Biol. 2022 Apr 20;67(9):10.1088/1361-6560/ac637e. doi: 10.1088/1361-6560/ac637e. Phys Med Biol. 2022. PMID: 35366658 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources