Intravenous in-line filters for preventing morbidity and mortality in neonates
- PMID: 16625631
- DOI: 10.1002/14651858.CD005248.pub2
Intravenous in-line filters for preventing morbidity and mortality in neonates
Update in
-
Intravenous in-line filters for preventing morbidity and mortality in neonates.Cochrane Database Syst Rev. 2015 Aug 6;2015(8):CD005248. doi: 10.1002/14651858.CD005248.pub3. Cochrane Database Syst Rev. 2015. PMID: 26244380 Free PMC article.
Abstract
Background: Venous access is an essential part of caring for the sick neonate; however, problems such as contamination of fluids with bacteria, endotoxins and particulates have been associated with intravenous infusion therapy. Intravenous in-line filters claim to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults and are increasingly being recommended for use in neonates.
Objectives: To assess whether in-line filters on intravenous lines prevent morbidity and mortality in neonates.
Search strategy: Searches were made of the electronic databases MEDLINE (from 1966 to September 2005), EMBASE (from 1980 to September 2005), CINAHL (from 1982 to September 2005) and the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 3 2005 ). There was no language restriction. Further searching included cross references, abstracts, conferences, symposia proceedings, expert informants and journal handsearching.
Selection criteria: Randomized or quasi-randomized controlled trials that compared the use of intravenous in-line filters with placebo or nothing in neonates were included in the review.
Data collection and analysis: The procedures of the Cochrane Neonatal Review Group (CNRG) were followed throughout. Titles and abstracts identified from the search were checked by the review authors. The full text of all studies of possible relevance were obtained. The review authors independently assessed the trials for their methodological quality and subsequent inclusion in the review. Statistical analysis followed the procedures of the Cochrane Neonatal Review Group. Dichotomous data is expressed as relative risk and 95% confidence intervals, and risk difference and 95% confidence intervals.
Main results: There were three eligible studies, which recruited a total of 262 neonates. For most of the outcomes for this review, only one study of 88 neonates contributed eligible data. This review found no significant effect of in-line filters in any of the reported outcomes of overall mortality, proven and unproven septicaemia, phlebitis, necrotizing enterocolitis, duration of cannula patency, number of catheters inserted and financial costs.
Authors' conclusions: There are insufficient data to determine whether or not the use of intravenous in-line filters prevent morbidity and mortality in neonates. The wide confidence intervals on outcomes indicate the imprecise estimates of treatment effect due to the small numbers of patients and events.