Update on safety of diagnostic ultrasonography
Abstract
Safety considerations for diagnostic ultrasonography have gradually changed as new instruments, not only more powerful in performance but also in ultrasonic exposure, have come into use. Nonthermal cavitational bioeffects of ultrasound have a problematic role in risk assessment for clinical applications, but should serve as cautionary reminders that there potentially could be low-level risks. Recent analyses have indicated possible areas of concern related to the thermal mechanism of bioeffects, particularly if trends for higher intensities continue into the future. The most critical area of concern is in fetal examinations, for which developing bone is unavoidably heated by relatively powerful pulsed-Doppler beams. Fortunately, because of the threshold nature of thermal damage, development of flexible, use-driven upper limits on output should completely resolve this impending safety problem. The ultrasonics community is now responding to these evolving safety issues with improved instrument characterization standards, new bioeffects research, and initiatives in continuing education for sonographers.
Similar articles
-
Safety assurance in obstetrical ultrasound.Semin Ultrasound CT MR. 2008 Apr;29(2):156-64. doi: 10.1053/j.sult.2007.12.003. Semin Ultrasound CT MR. 2008. PMID: 18450141 Free PMC article. Review.
-
Guidelines and recommendations for safe use of Doppler ultrasound in perinatal applications.J Matern Fetal Med. 2001 Apr;10(2):75-84. doi: 10.1080/714904312. J Matern Fetal Med. 2001. PMID: 11392597
-
Impact of safety considerations on ultrasound equipment design and use.Clin Diagn Ultrasound. 1993;28:151-60. Clin Diagn Ultrasound. 1993. PMID: 8476642 Review. No abstract available.
-
A new safety parameter for diagnostic ultrasound thermal bioeffects: safe use time.J Acoust Soc Am. 2009 Jun;125(6):3601-10. doi: 10.1121/1.3126525. J Acoust Soc Am. 2009. PMID: 19507942
-
[Obstetrical ultrasound: can the fetus hear the wave and feel the heat?].Ultraschall Med. 2012 Jun;33(3):215-7. doi: 10.1055/s-0032-1312759. Epub 2012 Jun 14. Ultraschall Med. 2012. PMID: 22700164 German.
Cited by
-
Clinical and research applications of real-time ultrasonography in bovine reproduction: a review.Can Vet J. 1994 Sep;35(9):563-72. Can Vet J. 1994. PMID: 7994719 Free PMC article. Review.
-
Ultrasound Image Optimization ("Knobology"): B-Mode.Ultrasound Int Open. 2020 Jun;6(1):E14-E24. doi: 10.1055/a-1223-1134. Epub 2020 Aug 31. Ultrasound Int Open. 2020. PMID: 32885137 Free PMC article. Review.
-
Anchoring Microbubbles on Cerebrovascular Endothelium as a New Strategy Enabling Low-Energy Ultrasound-Assisted Delivery of Varisized Agents Across Blood-Brain Barrier.Adv Sci (Weinh). 2023 Nov;10(33):e2302134. doi: 10.1002/advs.202302134. Epub 2023 Oct 23. Adv Sci (Weinh). 2023. PMID: 37870165 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources