Entropy
- PMID: 16634417
- DOI: 10.1016/j.bpa.2005.07.009
Entropy
Abstract
The concept of entropy, originally derived from thermodynamics, has been successfully applied to EEG analysis. Various entropy algorithms have been used in clinical studies, but until now a commercially available monitor exists only for spectral entropy. By calculating two distinct values for the EEG dominated part of the spectrum (state entropy, SE) and the total spectrum (response entropy, RE), the M-Entropy module claims to provide useful information regarding the cortical state of the patient as well as an indirect measure of adequacy of analgesia. Generally, entropy has been studied for quantification of anaesthetic drug effect for various GABA-ergic i.v. induction agents and volatile anaesthetics like propofol and sevoflurane and overall was found comparable to the current clinical gold standard bispectral index (BIS). Entropy guidance may not be used during ketamine or nitrous oxide administration, since there is no reliable correlation to the patient's state of consciousness. The usefulness of RE as a surrogate for increased EMG activity due to painful stimulation has not been proven so far.
Similar articles
-
Entropy of EEG during anaesthetic induction: a comparative study with propofol or nitrous oxide as sole agent.Br J Anaesth. 2004 Feb;92(2):167-70. doi: 10.1093/bja/aeh036. Br J Anaesth. 2004. PMID: 14722164 Clinical Trial.
-
Permutation entropy of the electroencephalogram: a measure of anaesthetic drug effect.Br J Anaesth. 2008 Dec;101(6):810-21. doi: 10.1093/bja/aen290. Epub 2008 Oct 12. Br J Anaesth. 2008. PMID: 18852113
-
Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals: a comparison with two randomised anaesthetic techniques.Eur J Anaesthesiol. 2015 May;32(5):354-65. doi: 10.1097/EJA.0000000000000189. Eur J Anaesthesiol. 2015. PMID: 25564779 Clinical Trial.
-
[Monitoring intraoperative awareness. Vegetative signs, isolated forearm technique, electroencephalogram, and acute evoked potentials].Anaesthesist. 1996 Aug;45(8):708-21. doi: 10.1007/s001010050303. Anaesthesist. 1996. PMID: 8967583 Review. German.
-
[Bispectral analysis of the electroencephalogram: a new method for recording the level of consciousness during anaesthesia].Ned Tijdschr Geneeskd. 2004 Jun 26;148(26):1276-80. Ned Tijdschr Geneeskd. 2004. PMID: 15279209 Review. Dutch.
Cited by
-
Bitcoin Money Laundering Detection via Subgraph Contrastive Learning.Entropy (Basel). 2024 Feb 28;26(3):211. doi: 10.3390/e26030211. Entropy (Basel). 2024. PMID: 38539723 Free PMC article.
-
Effects of etomidate on bispectral index scale and spectral entropy during induction of anesthesia by means of the raw electroencephalographic and electromyographic characteristics.Korean J Anesthesiol. 2012 Mar;62(3):230-3. doi: 10.4097/kjae.2012.62.3.230. Epub 2012 Mar 21. Korean J Anesthesiol. 2012. PMID: 22474548 Free PMC article.
-
SEMG-based hand motion recognition using cumulative residual entropy and extreme learning machine.Med Biol Eng Comput. 2013 Apr;51(4):417-27. doi: 10.1007/s11517-012-1010-9. Epub 2012 Dec 6. Med Biol Eng Comput. 2013. PMID: 23224795
-
Research progress on the depth of anesthesia monitoring based on the electroencephalogram.Ibrain. 2024 Dec 6;11(1):32-43. doi: 10.1002/ibra.12186. eCollection 2025 Spring. Ibrain. 2024. PMID: 40103697 Free PMC article. Review.
-
Correlation of surgical pleth index with stress hormones during propofol-remifentanil anaesthesia.ScientificWorldJournal. 2012;2012:879158. doi: 10.1100/2012/879158. Epub 2012 Sep 2. ScientificWorldJournal. 2012. PMID: 22973178 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Medical
Miscellaneous