Clinical Trial
. 2006 May;27(5):S129-37.
doi: 10.1088/0967-3334/27/5/S11. Epub 2006 Apr 20.

Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system

Affiliations
Clinical Trial

Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system

S Nebuya et al. Physiol Meas. 2006 May.

Abstract

Inter-subject variability has caused the majority of previous electrical impedance tomography (EIT) techniques to focus on the derivation of relative or difference measures of in vivo tissue resistivity. Implicit in these techniques is the requirement for a reference or previously defined data set. This study assesses the accuracy and optimum electrode placement strategy for a recently developed method which estimates an absolute value of organ resistivity without recourse to a reference data set. Since this measurement of tissue resistivity is absolute, in Ohm metres, it should be possible to use EIT measurements for the objective diagnosis of lung diseases such as pulmonary oedema and emphysema. However, the stability and reproducibility of the method have not yet been investigated fully. To investigate these problems, this study used a Sheffield Mk3.5 system which was configured to operate with eight measurement electrodes. As a result of this study, the absolute resistivity measurement was found to be insensitive to the electrode level between 4 and 5 cm above the xiphoid process. The level of the electrode plane was varied between 2 cm and 7 cm above the xiphoid process. Absolute lung resistivity in 18 normal subjects (age 22.6 +/- 4.9, height 169.1 +/- 5.7 cm, weight 60.6 +/- 4.5 kg, body mass index 21.2 +/- 1.6: mean +/- standard deviation) was measured during both normal and deep breathing for 1 min. Three sets of measurements were made over a period of several days on each of nine of the normal male subjects. No significant differences in absolute lung resistivity were found, either during normal tidal breathing between the electrode levels of 4 and 5 cm (9.3 +/- 2.4 Omega m, 9.6 +/- 1.9 Omega m at 4 and 5 cm, respectively: mean +/- standard deviation) or during deep breathing between the electrode levels of 4 and 5 cm (10.9 +/- 2.9 Omega m and 11.1 +/- 2.3 Omega m, respectively: mean +/- standard deviation). However, the differences in absolute lung resistivity between normal and deep tidal breathing at the same electrode level are significant. No significant difference was found in the coefficient of variation between the electrode levels of 4 and 5 cm (9.5 +/- 3.6%, 8.5 +/- 3.2% at 4 and 5 cm, respectively: mean +/- standard deviation in individual subjects). Therefore, the electrode levels of 4 and 5 cm above the xiphoid process showed reasonable reliability in the measurement of absolute lung resistivity both among individuals and over time.