Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye

Affiliations

Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye

Kunitoshi Fujisawa et al. Graefes Arch Clin Exp Ophthalmol. 2007 Jan.

Abstract

Background: Insertion of a phakic IOL offers these advantages: the corneal optical zone is not dissected or resected; preservation of the crystalline lens results in preservation of the accommodation force; and since the phakic IOL is removable, any error or change in refraction can be countered by exchanging it. However, the cause of secondary cataracts has never been clarified or discussed to date.

Methods: The following ICL lenses were inserted under general anaesthesia into 20 eyes of ten 3-month-old miniature pigs: a minus lens without holes into five eyes, a plus lens in two eyes, a minus lens with four holes around the lens haptics in three eyes, and a minus lens with a central hole in the optic in three eyes; and seven eyes were used as controls. The anterior segments were then photographed 1 week, 1 month and 3 months after surgery. At 3 months after surgery, Evans blue (EB) was infused into the vitreous under general anaesthesia, and after 30 min, the eyeball was enucleated, fixed and examined.

Results: In the case of the ICL without holes, the anterior subcapsular opacities were observed in all the eyes, and the anterior surfaces of the crystalline lenses were not stained with EB. Use of the ICL with four holes around the lens haptics resulted in light staining of the anterior surface of the crystalline lens, but the anterior subcapsular opacities observed were mild. As for the ICL with a hole in the centre of the optic, the anterior surface of the crystalline lens was stained and no anterior subcapsular opacities were observed.

Conclusion: The results suggested that the insertion of an ICL brings about a change in the dynamics of the intraocular aqueous humour, reducing its circulation to the anterior surface of the crystalline lens. This is considered to cause a metabolic disturbance of the crystalline lens, resulting in anterior subcapsular opacification.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Cataract Refract Surg. 2001 Mar;27(3):380-8 - PubMed
    1. J Cataract Refract Surg. 1999 Feb;25(2):278-82 - PubMed
    1. J Cataract Refract Surg. 2004 Mar;30(3):576-83 - PubMed
    1. J Cataract Refract Surg. 2003 May;29(5):918-24 - PubMed
    1. Invest Ophthalmol. 1969 Apr;8(2):133-49 - PubMed

LinkOut - more resources