Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 May;47(5):763-9.

PET-based human dosimetry of 18F-galacto-RGD, a new radiotracer for imaging alpha v beta3 expression

Affiliations
  • PMID: 16644745
Free article

PET-based human dosimetry of 18F-galacto-RGD, a new radiotracer for imaging alpha v beta3 expression

Ambros J Beer et al. J Nucl Med. 2006 May.
Free article

Abstract

(18)F-Galacto-RGD is a new tracer for PET imaging of alpha v beta3, a receptor involved in a variety of pathologic processes including angiogenesis and metastasis. Our aim was to study the dosimetry of (18)F-galacto-RGD in humans.

Methods: Eighteen patients with various tumors (musculoskeletal tumors [n = 10], melanoma [n = 5], breast cancer [n = 2], or head and neck cancer [n = 1]) were examined. After injection of 133-200 MBq of (18)F-galacto-RGD, 3 consecutive emission scans from the thorax to the pelvis were acquired at 6.7 +/- 2.9, 35.6 +/- 7.6, and 70.4 +/- 12.2 min after injection. Blood samples (n = 4) for metabolite analysis were taken 10, 30, and 120 min after injection. The OLINDA 1.0 program was used to estimate the absorbed radiation dose.

Results: Reversed-phase high-performance liquid chromatography of serum revealed that more than 95% of tracer was intact up to 120 min after injection. (18)F-Galacto-RGD showed rapid clearance from the blood pool and primarily renal excretion. Background activity in lung and muscle tissue was low (percentage injected dose per liter at 71 min after injection, 0.56 +/- 0.15 and 0.69 +/- 0.25, respectively). The calculated effective dose was 18.7 +/- 2.4 microSv/MBq, and the highest absorbed radiation dose was in the bladder wall (0.22 +/- 0.03 mGy/MBq).

Conclusion: (18)F-Galacto-RGD demonstrates high metabolic stability, a favorable biodistribution, and a low radiation dose. Consequently, this tracer can safely be used for noninvasive imaging of molecular processes involving the alpha v beta3 integrin and for the planning and monitoring of therapeutic approaches targeting alpha v beta3.

PubMed Disclaimer

Publication types

LinkOut - more resources