Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Sep;291(3):G525-31.
doi: 10.1152/ajpgi.00081.2006. Epub 2006 Apr 27.

Deglutitive upper esophageal sphincter relaxation: a study of 75 volunteer subjects using solid-state high-resolution manometry

Affiliations
Free article

Deglutitive upper esophageal sphincter relaxation: a study of 75 volunteer subjects using solid-state high-resolution manometry

Sudip K Ghosh et al. Am J Physiol Gastrointest Liver Physiol. 2006 Sep.
Free article

Abstract

This study aimed to use a novel high-resolution manometry (HRM) system to establish normative values for deglutitive upper esophageal sphincter (UES) relaxation. Seventy-five asymptomatic controls were studied. A solid-state HRM assembly with 36 circumferential sensors spaced 1 cm apart was positioned to record from the hypopharynx to the stomach. Subjects performed ten 5-ml water swallows and one each of 1-, 10-, and 20-ml volume swallows. Pressure profiles across the UES were analyzed using customized computational algorithms that measured 1) the relaxation interval (RI), 2) the median intrabolus pressure (mIBP) during the RI, and 3) the deglutitive sphincter resistance (DSR) defined as mIBP/RI. The automated analysis succeeded in confirming bolus volume modulation of both the RI and the mIBP with the mean RI ranging from 0.32 to 0.50 s and mIBP ranging from 5.93 to 13.80 mmHg for 1- and 20-ml swallows, respectively. DSR was relatively independent of bolus volume. Peak pharyngeal contraction during the return to the resting state postswallow was almost 300 mmHg, again independent of bolus volume. We performed a detailed analysis of deglutitive UES relaxation with a novel HRM system and customized software. The enhanced spatial resolution of HRM allows for the accurate, automated assessment of UES relaxation and intrabolus pressure characteristics, in both cases confirming the volume-dependent effects and absolute values of these parameters previously demonstrated by detailed analysis of concurrent manometry/fluoroscopy data. Normative values were established to aid in future clinical and investigative studies.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources