. 2006 Apr 1;40(7):2304-15.
doi: 10.1021/es051335p.

Simulating the effect of aerobic biodegradation on soil vapor intrusion into buildings: influence of degradation rate, source concentration, and depth

Affiliations

Simulating the effect of aerobic biodegradation on soil vapor intrusion into buildings: influence of degradation rate, source concentration, and depth

Lilian D V Abreu et al. Environ Sci Technol. .

Abstract

Steady-state vapor intrusion scenarios involving aerobically biodegradable chemicals are studied using a three-dimensional multicomponent numerical model. In these scenarios, sources of aerobically biodegradable chemical vapors are placed at depths of 1-14 m beneath a 10 m x 10 m basement or slab-on-grade construction building, and the simultaneous transport and reaction of hydrocarbon and oxygen vapors are simulated. The results are presented as Johnson and Ettinger attenuation factors alpha (predicted indoor air hydrocarbon concentration/source vapor concentration), and normalized contour plots of hydrocarbon and oxygen concentrations. In addition to varying the vapor source depth, the effects of source concentration (2-200 mg chemical/L vapor) and oxygen-limited first-order reaction rates (0.018-1.8 h(-1)) are studied. Hydrocarbon inputs were specific to benzene, although the relevant properties are similar to those for a range of hydrocarbons of interest. Overall, the results suggest that aerobic biodegradation could play a significant role in reducing vapor intrusion into buildings (decreased alpha-values) relative to the no-biodegradation case, with the significance of aerobic biodegradation increasing with increasing vapor source depth, decreasing vapor source concentration, and increasing first-order biodegradation rate. In contrast to the no-biodegradation case, differences in foundation construction can be significant in some settings. The significance of aerobic biodegradation is directly related to the extent to which oxygen is capable of migrating beneath the foundation. For example, in the case of a basement scenario with a 200 mg/L vapor source located at 3 m bgs, oxygen is consumed before it can migrate beneath the foundation, so the attenuation factors for simulations with and without aerobic biodegradation are similar for all first-order rates studied. For the case of a 2 mg/L vapor source located at 8 m bgs, the oxygen is widely distributed beneath the foundation, and the attenuation factor for the biodegradation case ranges from about 3 to 18 orders-of-magnitude less than that for the no-biodegradation case.

PubMed Disclaimer