Thoracoscopic repair of esophageal atresia and tracheoesophageal fistula: lessons learned
- PMID: 16646712
- DOI: 10.1089/lap.2006.16.174
Thoracoscopic repair of esophageal atresia and tracheoesophageal fistula: lessons learned
Abstract
Objective: Repair of esophageal atresia and tracheoesophageal fistula has traditionally been performed via thoracotomy. This study aims to evaluate the feasibility and pitfalls of the thoracoscopic approach.
Materials and methods: Six consecutive patients with type C tracheoesophageal fistulae underwent thoracoscopic repair. The operation was approached through the right chest using a three-trocar technique (two 5-mm and one 3-mm) with the patient placed in a three-quarter prone position. Patient characteristics, operative time, duration of narcotic usage, conversion factors, postoperative complications, and long-term follow-up were recorded.
Results: Five of six patients were successfully operated on thoracoscopically. The average operative time was 143 minutes (range, 75-215 minutes) with repair of long-gap defects requiring significantly longer times than short-gap defects (200 vs. 129 minutes, P < 0.05). There were no intraoperative complications. Mean duration of narcotic use was 52 hours (range, 24-72 hours). There were no anastomotic leaks. One patient developed an anastomotic stricture at the third postoperative week, which resolved with two dilations. One patient died on the first postoperative day from respiratory failure.
Conclusion: Thoracoscopic repair of esophageal atresia and tracheoesophageal fistula is feasible, but is technically challenging. Long-gap defects require more extensive dissection and difficult anastomosis, and are therefore associated with longer operative times. More data are needed for further evaluation of this approach.