Role of stent design and coatings on restenosis and thrombosis
- PMID: 16650911
- DOI: 10.1016/j.addr.2006.01.022
Role of stent design and coatings on restenosis and thrombosis
Abstract
More than 15 years have passed since stent technology was introduced by Sigwart et al. [U. Sigwart, J. Puel, V. Mirkovitch, F. Joffe, et al. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N. Engl. J. Med. 316 (1987) 701-706.] among interventional cardiologists. Recently drug eluting stents have assumed dominance in the interventional world as positive trial results revealed their efficacy for preventing restenosis. Stent design, delivery-vehicle materials, and drug properties affect the function of these stents. Stainless steel stents with tubular and multicellular design have proven superior to coil or hybrid stent models. This chapter describes stents which have subtle influences of modular design, metal coverage, strut thickness, strut shape, surface smoothness, and coating materials like an alloy composition.
Similar articles
-
A stent is not just a stent: Stent construction and design do matter in its clinical performance.Singapore Med J. 2004 Jul;45(7):305-11; quiz 312. Singapore Med J. 2004. PMID: 15221045 Review.
-
The influence of physical stent parameters upon restenosis.Pathol Biol (Paris). 2004 May;52(4):196-205. doi: 10.1016/j.patbio.2004.03.013. Pathol Biol (Paris). 2004. PMID: 15145132 Review.
-
Drug-eluting stents.Arch Cardiol Mex. 2006 Jul-Sep;76(3):297-319. Arch Cardiol Mex. 2006. PMID: 17091802 Review.
-
Drug-eluting stents: a multidisciplinary success story.Adv Drug Deliv Rev. 2006 Jun 3;58(3):350-7. doi: 10.1016/j.addr.2006.01.014. Epub 2006 Mar 20. Adv Drug Deliv Rev. 2006. PMID: 16546288 Review.
-
Passive stent coatings in the drug-eluting era.J Invasive Cardiol. 2005 Apr;17(4):222-8. J Invasive Cardiol. 2005. PMID: 15831978 Review.
Cited by
-
A heparin-rosuvastatin-loaded P(LLA-CL) nanofiber-covered stent inhibits inflammatory smooth-muscle cell viability to reduce in-stent stenosis and thrombosis.J Nanobiotechnology. 2021 Apr 29;19(1):123. doi: 10.1186/s12951-021-00867-8. J Nanobiotechnology. 2021. PMID: 33926468 Free PMC article.
-
Bio-inspired hemocompatible surface modifications for biomedical applications.Prog Mater Sci. 2022 Oct;130:100997. doi: 10.1016/j.pmatsci.2022.100997. Epub 2022 Jun 17. Prog Mater Sci. 2022. PMID: 36660552 Free PMC article.
-
Computational simulation of platelet interactions in the initiation of stent thrombosis due to stent malapposition.Phys Biol. 2016 Jan 20;13(1):016001. doi: 10.1088/1478-3975/13/1/016001. Phys Biol. 2016. PMID: 26790093 Free PMC article.
-
A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms.PLoS One. 2017 Aug 9;12(8):e0182717. doi: 10.1371/journal.pone.0182717. eCollection 2017. PLoS One. 2017. PMID: 28793343 Free PMC article.
-
Clinical outcomes and complications of treatment with supraflex stent in patients with coronary artery disease: One-year follow-up.Eur J Transl Myol. 2019 May 22;29(2):8231. doi: 10.4081/ejtm.2019.8231. eCollection 2019 May 7. Eur J Transl Myol. 2019. PMID: 31354927 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical