A Cuvette Design for Measurement of Ethylene Production and Carbon Dioxide Exchange by Intact Shoots under Controlled Environmental Conditions
- PMID: 16660994
- PMCID: PMC543119
- DOI: 10.1104/pp.64.3.488
A Cuvette Design for Measurement of Ethylene Production and Carbon Dioxide Exchange by Intact Shoots under Controlled Environmental Conditions
Abstract
A cuvette is described for simultaneous measurement of ethylene production and CO(2) fixation by intact shoots under controlled environmental conditions. This design overcomes potential problems associated with closed systems conventionally used for studies on ethylene production, allowing accurate determination of rates of ethylene production in plants exposed to different environmental conditions.
References