Silicone hydrogel contact lenses and the ocular surface
- PMID: 16669523
- DOI: 10.1016/s1542-0124(12)70262-8
Silicone hydrogel contact lenses and the ocular surface
Abstract
For 30 years, contact lens research focused on the need for highly oxygen-permeable (Dk) soft lens materials. High Dk silicone hydrogel contact lenses, made available in 1999, met this need. The purpose of this review is to examine how silicone hydrogel lens wear affects the ocular surfaces and to highlight areas in which further research is needed to improve biocompatibility. Silicone hydrogel lenses have eliminated lens-induced hypoxia for the majority of wearers and have a less pronounced effect on corneal homeostasis compared to other lens types; however, mechanical interaction with ocular tissue and the effects on tear film structure and physiology are similar to that found with soft lens wear in general. Although the ocular health benefits of silicone hydrogel lenses have increased the length of time lenses can be worn overnight, the risk of infection is similar to that found with other soft lens types, and overnight wear remains a higher risk factor for infection than daily wear, regardless of lens material. Future contact lens research will focus on gaining a better understanding of the way in which contact lenses interact with the corneal surface, upper eyelid, and the tear film, and the lens-related factors contributing to infection and inflammatory responses.
Similar articles
-
A 1-year prospective clinical trial of balafilcon a (PureVision) silicone-hydrogel contact lenses used on a 30-day continuous wear schedule.Ophthalmology. 2002 Jun;109(6):1172-7. doi: 10.1016/s0161-6420(02)01045-x. Ophthalmology. 2002. PMID: 12045062 Clinical Trial.
-
Mucin balls with wear of conventional and silicone hydrogel contact lenses.Optom Vis Sci. 2003 Apr;80(4):291-7. doi: 10.1097/00006324-200304000-00006. Optom Vis Sci. 2003. PMID: 12692485 Clinical Trial.
-
Bacterial populations on 30-night extended wear silicone hydrogel lenses.CLAO J. 2001 Jan;27(1):30-4. CLAO J. 2001. PMID: 11215603 Clinical Trial.
-
Risk of corneal inflammatory events with silicone hydrogel and low dk hydrogel extended contact lens wear: a meta-analysis.Optom Vis Sci. 2007 Apr;84(4):247-56. doi: 10.1097/OPX.0b013e3180421c47. Optom Vis Sci. 2007. PMID: 17435508 Review.
-
Thirty years of 'quiet eye' with etafilcon A contact lenses.Cont Lens Anterior Eye. 2020 Jun;43(3):285-297. doi: 10.1016/j.clae.2020.03.015. Epub 2020 Apr 8. Cont Lens Anterior Eye. 2020. PMID: 32278644 Review.
Cited by
-
The efficiency of contact lens care regimens on protein removal from hydrogel and silicone hydrogel lenses.Mol Vis. 2010 Jan 20;16:79-92. Mol Vis. 2010. PMID: 20098668 Free PMC article.
-
Atypical Presentation of Salzmann Nodular Corneal Degeneration as a Subepithelial Corneal Dystrophy: A Case Report.Cureus. 2022 Apr 20;14(4):e24328. doi: 10.7759/cureus.24328. eCollection 2022 Apr. Cureus. 2022. PMID: 35607543 Free PMC article.
-
Development of ciprofloxacin-loaded contact lenses using fluorous chemistry.Biomaterials. 2017 Apr;124:55-64. doi: 10.1016/j.biomaterials.2017.01.046. Epub 2017 Jan 31. Biomaterials. 2017. PMID: 28188995 Free PMC article.
-
Topical review: Twenty-five years of silicone hydrogel soft contact lenses.Optom Vis Sci. 2025 Jun 1;102(6):361-374. doi: 10.1097/OPX.0000000000002267. Epub 2025 Jun 20. Optom Vis Sci. 2025. PMID: 40549698 Free PMC article. Review.
-
Effects of Lotrafilcon A and Senofilcon A Bandage Contact Lenses on Visual Outcome and Ocular Comfort After Photorefractive Keratectomy.Turk J Ophthalmol. 2024 Dec 31;54(6):318-323. doi: 10.4274/tjo.galenos.2024.03392. Turk J Ophthalmol. 2024. PMID: 39743926 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous