Comparative Study
. 2006 Sep;291(3):L535-45.
doi: 10.1152/ajplung.00088.2005. Epub 2006 May 5.

Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography

Affiliations
Free article
Comparative Study

Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography

Horst Detlef Litzlbauer et al. Am J Physiol Lung Cell Mol Physiol. 2006 Sep.
Free article

Abstract

We evaluated microfocal X-ray-computed tomography (micro-CT) as a method to visualize lung architecture two and three dimensionally and to obtain morphometric data. Inflated porcine lungs were fixed by formaldehyde ventilation. Tissue samples (8-mm diameter, 10-mm height) were stained with osmium tetroxide, and 400 projection images (1,024 x 1,024 pixel) were obtained. Continuous isometric micro-CT scans (voxel size 9 microm) were acquired to reconstruct two- and three-dimensional images. Tissue samples were sectioned (8-microm thickness) for histological analysis. Alveolar surface density and mean linear intercept were assessed by stereology-based morphometry in micro-CT scans and corresponding histological sections. Furthermore, stereology-based morphometry was compared with morphometric semi-automated micro-CT analysis within the same micro-CT scan. Agreement of methods was assessed by regression and Bland-Altman analysis. Comparing histology with micro-CT, alveolar surface densities (35.4 +/- 2.4 vs. 33.4 +/- 1.9/mm, P < 0.05) showed a correlation (r = 0.72; P = 0.018) with an agreement of 2 +/- 1.6/mm; the mean linear intercept (135.7 +/- 14.5 vs. 135.8 +/- 15 microm) correlated well (r = 0.97; P < 0.0001) with an agreement of -0.1 +/- 3.4 microm. Semi-automated micro-CT analysis resulted in smaller alveolar surface densities (33.4 +/- 1.9 vs. 30.5 +/- 1/mm; P < 0.01) with a correlation (r = 0.70; P = 0.023) and agreement of 2.9 +/- 1.4/mm. Non-destructive micro-CT scanning offers the advantage to visualize the spatial tissue architecture of small lung samples two and three dimensionally.