Closed-loop resuscitation of burn shock
- PMID: 16679909
- DOI: 10.1097/01.BCR.0000216512.30415.78
Closed-loop resuscitation of burn shock
Abstract
Fluid therapy for burn shock is adjusted to establish a target level of urinary output. However, the means for adjusting infusion rate are not defined. Our objective was to compare the performance of automated computer-controlled resuscitation with manual control for burn resuscitation. Sheep with a 40% TBSA full-thickness burn, administered under halothane anesthesia, were resuscitated to restore and maintain normal sheep urinary outputs in a target range of 1 to 2 ml/kg per hour over the course of 48 hours using closed-loop resuscitation (n = 10) or manual hourly adjustment of infusion rate (n = 11). The automated closed-loop resuscitation system is based on a proportional-integral-derivative algorithm, which adjusted infusion rate based on continuous monitoring and changes in urinary output. Mean urinary outputs over the course of 48 hours were in target range and were virtually identical at 1.9 +/- 0.5 ml/kg per hour for the closed-loop group and 2.0 +/- 0.7 ml/kg per hour for the technician group. Mean infusion rates and infused volumes also were similar. The closed-loop group exhibited significantly lower hourly variation for both urinary output and infusion rate compared hourly control. Hourly targets were achieved in 41% of the measurements in technician group compared with 48% for the closed-loop group (P = .23). Hourly urinary output in the technician group was undertarget by 25% as opposed to 16% with the closed-loop group (P = .02). Automated closed-loop control of infusion rates after burn injury produced urinary outputs in target ranges with less variation and less under target values than manual hourly adjustments. Closed-loop resuscitation may provide an improvement over current resuscitation regimens.
Similar articles
-
Closed-loop and decision-assist resuscitation of burn patients.J Trauma. 2008 Apr;64(4 Suppl):S321-32. doi: 10.1097/TA.0b013e31816bf4f7. J Trauma. 2008. PMID: 18385584 Review.
-
Computerized decision support system improves fluid resuscitation following severe burns: an original study.Crit Care Med. 2011 Sep;39(9):2031-8. doi: 10.1097/CCM.0b013e31821cb790. Crit Care Med. 2011. PMID: 21532472 Clinical Trial.
-
High-dose vitamin C infusion reduces fluid requirements in the resuscitation of burn-injured sheep.Shock. 2005 Aug;24(2):139-44. doi: 10.1097/01.shk.0000170355.26060.e6. Shock. 2005. PMID: 16044084
-
Protocolized Resuscitation of Burn Patients.Crit Care Clin. 2016 Oct;32(4):599-610. doi: 10.1016/j.ccc.2016.06.008. Epub 2016 Aug 3. Crit Care Clin. 2016. PMID: 27600131 Review.
-
CLOSED-LOOP VENTILATION AND OXYGENATION WITH DECISION SUPPORT FLUID RESUSCITATION TO TREAT MAJOR BURN INJURY WITH SMOKE-INDUCED ACUTE RESPIRATORY DISTRESS SYNDROME.Shock. 2025 May 1;63(5):781-787. doi: 10.1097/SHK.0000000000002552. Epub 2025 Jan 22. Shock. 2025. PMID: 39840968
Cited by
-
Modeling Fluid Resuscitation by Formulating Infusion Rate and Urine Output in Severe Thermal Burn Adult Patients: A Retrospective Cohort Study.Biomed Res Int. 2015;2015:508043. doi: 10.1155/2015/508043. Epub 2015 May 10. Biomed Res Int. 2015. PMID: 26090415 Free PMC article.
-
Performance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials.J Clin Monit Comput. 2024 Feb;38(1):5-18. doi: 10.1007/s10877-023-01069-3. Epub 2023 Sep 11. J Clin Monit Comput. 2024. PMID: 37695449
-
Pediatric burn resuscitation: past, present, and future.Burns Trauma. 2017 Sep 4;5:26. doi: 10.1186/s41038-017-0091-y. eCollection 2017. Burns Trauma. 2017. PMID: 28879205 Free PMC article. Review.
-
MAN VERSUS MACHINE: PROVIDER DIRECTED VERSUS PRECISION AUTOMATED CRITICAL CARE MANAGEMENT IN A PORCINE MODEL OF DISTRIBUTIVE SHOCK.Shock. 2024 May 1;61(5):758-765. doi: 10.1097/SHK.0000000000002345. Epub 2024 Mar 25. Shock. 2024. PMID: 38526148 Free PMC article.
-
Peripheral intravenous infusion for children based on computer digital video technology.Am J Transl Res. 2023 Jan 15;15(1):466-475. eCollection 2023. Am J Transl Res. 2023. PMID: 36777820 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical