Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jun;69(6):515-23.
doi: 10.1002/cyto.a.20273.

Method for monitoring of mitochondrial cytochrome c release during cell death: Immunodetection of cytochrome c by flow cytometry after selective permeabilization of the plasma membrane

Affiliations
Free article

Method for monitoring of mitochondrial cytochrome c release during cell death: Immunodetection of cytochrome c by flow cytometry after selective permeabilization of the plasma membrane

Claudia B L Campos et al. Cytometry A. 2006 Jun.
Free article

Abstract

Background: Cytochrome c release from mitochondria to cytosol is a hallmark of apoptosis and is used to characterize the mitochondria-dependent pathway of this type of cell death. Techniques currently used to measure cytochrome c release, Western blot and fluorescence microscopy of immunolabeled cells, are time-consuming and inaccurate, and the latter is still limited by sample size.

Methods: We developed a rapid and reliable technique to detect cytochrome c release during drug-induced apoptosis, using flow cytometry. Plasma membrane of apoptotic HL-60 cells and thymocytes, treated with staurosporine and dexamethasone, respectively, were selectively permeabilized by digitonin at a low concentration. The released cytochrome c was quickly washed out from cells and that which remained in the mitochondria was immunolabeled after fixing the cells.

Results: The fraction of cells that retained their mitochondrial cytochrome c, or the highly fluorescent cells, gradually decreased so that after 4-8 h of drug treatment almost all the cells lost their cytochrome c and emerged as a population of low fluorescent cells. This was confirmed by parallel fluorescence microscopy of cells immunolabeled for cytochrome c.

Conclusions: This technique allows the analysis of cytochrome c release from mitochondria of a large number of apoptotic cells in a short period of time and is proposed as an alternative to the methods currently used for this same purpose.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources