Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches
- PMID: 16681446
- DOI: 10.1586/17434440.3.3.267
Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches
Similar articles
-
Research approaches for studying flow-induced thromboembolic complications in blood recirculating devices.Expert Rev Med Devices. 2004 Sep;1(1):65-80. doi: 10.1586/17434440.1.1.65. Expert Rev Med Devices. 2004. PMID: 16293011 Review.
-
Innovative developments of the heart valves designed for use in ventricular assist devices.Expert Rev Med Devices. 2005 Jan;2(1):61-71. doi: 10.1586/17434440.2.1.61. Expert Rev Med Devices. 2005. PMID: 16293030 Review.
-
The 12 cc Penn State pulsatile pediatric ventricular assist device: fluid dynamics associated with valve selection.J Biomech Eng. 2008 Aug;130(4):041019. doi: 10.1115/1.2939342. J Biomech Eng. 2008. PMID: 18601461
-
Towards non-thrombogenic performance of blood recirculating devices.Ann Biomed Eng. 2010 Mar;38(3):1236-56. doi: 10.1007/s10439-010-9905-9. Epub 2010 Feb 4. Ann Biomed Eng. 2010. PMID: 20131098 Free PMC article. Review.
-
Comparison of element technologies for modeling stent expansion.J Biomech Eng. 2006 Oct;128(5):751-6. doi: 10.1115/1.2264382. J Biomech Eng. 2006. PMID: 16995762
Cited by
-
Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulation.Biomech Model Mechanobiol. 2014 Apr;13(2):349-61. doi: 10.1007/s10237-012-0445-0. Epub 2012 Oct 6. Biomech Model Mechanobiol. 2014. PMID: 23053595 Free PMC article.
-
Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.J Biomech. 2010 Aug 26;43(12):2400-9. doi: 10.1016/j.jbiomech.2010.04.020. Epub 2010 May 21. J Biomech. 2010. PMID: 20483411 Free PMC article.
-
Biological effects of dynamic shear stress in cardiovascular pathologies and devices.Expert Rev Med Devices. 2008 Mar;5(2):167-81. doi: 10.1586/17434440.5.2.167. Expert Rev Med Devices. 2008. PMID: 18331179 Free PMC article. Review.
-
Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements.ASAIO J. 2008 Jan-Feb;54(1):64-72. doi: 10.1097/MAT.0b013e31815d6898. ASAIO J. 2008. PMID: 18204318 Free PMC article.
-
Parameterizing the Morse Potential for Coarse-Grained Modeling of Blood Plasma.J Comput Phys. 2014 Jan 15;257(Pt A):726-736. doi: 10.1016/j.jcp.2013.09.040. J Comput Phys. 2014. PMID: 24910470 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical