Report of a case receiving full-arch rehabilitation in both jaws using immediate implant loading protocols: a 1-year resonance frequency analysis follow-up
- PMID: 16681490
- DOI: 10.2310/j.6480.2005.00027.x
Report of a case receiving full-arch rehabilitation in both jaws using immediate implant loading protocols: a 1-year resonance frequency analysis follow-up
Abstract
Background: Immediate occlusal implant loading has been documented as a viable treatment option for various indications. However, documentations related to full-arch rehabilitation are usually limited to treatment of one jaw at a time, thereby leaving the opposing dentition unchanged. Furthermore, clinical documentation using traditional, well-accepted measuring techniques may not be adequate when it comes to short-term evaluation of the success or failure of implants subjected to immediate occlusal loading.
Purpose: The purpose of this case report is to (1) present an implant stability follow-up of a patient receiving an immediate, implant-supported full-arch rehabilitation in both jaws and (2) evaluate the patient's acceptance of this rehabilitation.
Materials and methods: A 68-year-old patient scheduled for implant treatment was selected for an immediate implant loading protocol in both jaws. During two surgical events 3 weeks apart, eight maxillary and four mandibular Brånemark System Mk IV TiUnite fixtures (Nobel Biocare AB, Göteborg, Sweden) were inserted and subsequently used to immediately support a cross-arch fixed prosthesis in the maxilla and a bar-retained overdenture in the mandible. Implant stability was recorded from the day of surgery periodically during a 1-year follow-up using resonance frequency analysis (RFA).
Results: At the 1-year follow-up, based on clinical, RFA, and radiographic evaluations, all implants and the reconstructions were classified as successful. All maxillary implants showed a decrease in the implant stability quotient (ISQ) value from the measurement at the time of surgery to the first follow-up, whereas two of four mandibular implants revealed an initial drop in stability. Irrespective of a specific ISQ level measured at implant surgery (ISQ range 53-74) and despite an initial decrease in stability, measurements recorded at the 12-month follow-up indicated similar stability levels for all maxillary implants (ISQ range 64-68) or the group of mandibular implants (ISQ range 72-75) but with a higher ISQ level for mandibular implants. Furthermore, the patient's acceptance of the immediate full-arch rehabilitation in both jaws was high.
Conclusions: The present case report demonstrates that a slightly staged approach for full-arch rehabilitation in both jaws using immediate implant loading protocols is a realistic treatment option. Furthermore, RFA follow-up indicates that immediately occlusally loaded implants placed in reduced bone quality and quantity are more prone to loose stability in the early healing period compared with implants placed in dense bone quality.
Similar articles
-
Immediate functional loading of TiOblast dental implants in full-arch edentulous maxillae: a 3-year prospective study.Clin Oral Implants Res. 2008 Dec;19(12):1254-60. doi: 10.1111/j.1600-0501.2008.01586.x. Clin Oral Implants Res. 2008. PMID: 19040440 Clinical Trial.
-
Five-year results of implants with an oxidized surface placed predominantly in soft quality bone and subjected to immediate occlusal loading.J Prosthet Dent. 2007 Jun;97(6 Suppl):S59-68. doi: 10.1016/S0022-3913(07)60009-2. J Prosthet Dent. 2007. PMID: 17618935
-
Immediate loading of dental implants placed in revascularized fibula free flaps: a clinical report on 2 consecutive patients.Int J Oral Maxillofac Implants. 2004 Nov-Dec;19(6):906-12. Int J Oral Maxillofac Implants. 2004. PMID: 15623070
-
Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications.Int J Oral Maxillofac Implants. 2004;19 Suppl:92-102. Int J Oral Maxillofac Implants. 2004. PMID: 15635949 Review.
-
Implant loading protocols for the partially edentulous esthetic zone.Int J Oral Maxillofac Implants. 2009;24 Suppl:169-79. Int J Oral Maxillofac Implants. 2009. PMID: 19885444 Review.
Cited by
-
Surface roughness implant-retained mandibular bar and ball joint overdentures and adherence of microorganisms.Eur J Dent. 2018 Oct-Dec;12(4):546-552. doi: 10.4103/ejd.ejd_265_18. Eur J Dent. 2018. PMID: 30369801 Free PMC article.
-
The stability of tetracalcium phosphate/titanium implants: A short-term follow-up study.J Dent Sci. 2022 Apr;17(2):1030-1034. doi: 10.1016/j.jds.2022.02.003. Epub 2022 Feb 23. J Dent Sci. 2022. PMID: 35756796 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical