Prognostic utility of microvolt T-wave alternans in risk stratification of patients with ischemic cardiomyopathy
- PMID: 16682307
- DOI: 10.1016/j.jacc.2005.11.079
Prognostic utility of microvolt T-wave alternans in risk stratification of patients with ischemic cardiomyopathy
Abstract
Objectives: The purpose of this study was to assess if microvolt T-wave alternans (MTWA) is an independent predictor of mortality in patients with ischemic cardiomyopathy.
Background: Microvolt T-wave alternans has been proposed as an effective tool for identifying high-risk patients with ischemic cardiomyopathy who are likely to benefit from implantable cardioverter-defibrillator (ICD) therapy. However, earlier studies have been limited in their ability to control for baseline differences between MTWA-negative and -non-negative (positive and indeterminate) patients.
Methods: We enrolled 768 consecutive patients with ischemic cardiomyopathy (left ventricular ejection fraction < or =35%) and no prior history of ventricular arrhythmia. All patients underwent baseline MTWA testing and were classified as MTWA negative or non-negative. Multivariable Cox regression analyses, stratified by ICD status, were used to determine the association between MTWA testing and mortality after adjusting for demographic, clinical, and treatment differences between MTWA-negative and -non-negative patients.
Results: We identified 514 (67%) patients with a non-negative MTWA test. After multivariable adjustment, a non-negative MTWA test was associated with a significantly higher risk for all-cause (stratified hazard ratio [HR] = 2.24 [95% confidence interval 1.34 to 3.75]; p = 0.002) and arrhythmic mortality (stratified HR = 2.29 [1.00 to 5.24]; p = 0.049) but not for nonarrhythmic mortality (stratified HR = 1.77 [0.84 to 3.74]; p = 0.13). In subgroup analyses, a non-negative MTWA test was also associated with a higher risk for all-cause mortality in patients with ejection fractions < or =30% (stratified HR = 2.10 [1.18 to 3.73]; p = 0.01) and after excluding those with indeterminate MTWA tests (stratified HR = 2.08 [1.18 to 3.66]; p = 0.01).
Conclusions: Microvolt T-wave alternans is a strong and independent predictor of all-cause and arrhythmic mortality in patients with ischemic cardiomyopathy.
Comment in
-
Can microvolt T-wave alternans predict mortality in patients with ischemic cardiomyopathy?Nat Clin Pract Cardiovasc Med. 2006 Sep;3(9):470-1. doi: 10.1038/ncpcardio0636. Nat Clin Pract Cardiovasc Med. 2006. PMID: 16932759 No abstract available.
Similar articles
-
Microvolt T-wave alternans identifies patients with ischemic cardiomyopathy who benefit from implantable cardioverter-defibrillator therapy.J Am Coll Cardiol. 2007 Jan 2;49(1):50-8. doi: 10.1016/j.jacc.2006.06.079. Epub 2006 Dec 13. J Am Coll Cardiol. 2007. PMID: 17207722
-
Usefulness of microvolt T-wave alternans on predicting outcome in patients with ischemic cardiomyopathy with and without defibrillators.Am J Cardiol. 2007 Aug 15;100(4):598-604. doi: 10.1016/j.amjcard.2007.03.069. Epub 2007 Jun 28. Am J Cardiol. 2007. PMID: 17697813
-
Prognostic implication of redefining indeterminate microvolt T-wave alternans studies as abnormal or normal.Am Heart J. 2007 Apr;153(4):523-9. doi: 10.1016/j.ahj.2006.12.021. Am Heart J. 2007. PMID: 17383288
-
Utility of microvolt T-wave alternans to predict sudden cardiac death in patients with cardiomyopathy.Curr Opin Cardiol. 2007 Jan;22(1):25-32. doi: 10.1097/HCO.0b013e328011aa49. Curr Opin Cardiol. 2007. PMID: 17143041 Review.
-
T-wave alternans and sudden cardiac death.Crit Pathw Cardiol. 2008 Mar;7(1):21-8. doi: 10.1097/HPC.0b013e318163f235. Crit Pathw Cardiol. 2008. PMID: 18458663 Review.
Cited by
-
T-wave alternans and ST depression assessment identifies low risk individuals with ischemic cardiomyopathy in the absence of left ventricular hypertrophy.Ann Noninvasive Electrocardiol. 2013 Jul;18(4):359-68. doi: 10.1111/anec.12051. Epub 2013 May 3. Ann Noninvasive Electrocardiol. 2013. PMID: 23879276 Free PMC article.
-
A restrictive inflow pattern does not predict implantable cardioverter-defibrillator therapy in primary prevention.Clin Cardiol. 2009 Dec;32(12):E32-5. doi: 10.1002/clc.20474. Clin Cardiol. 2009. PMID: 20014210 Free PMC article.
-
Microvolt T-wave alternans in end-stage renal disease patients--associations with uremic cardiomyopathy.Clin J Am Soc Nephrol. 2011 Mar;6(3):519-27. doi: 10.2215/CJN.06370710. Epub 2010 Nov 18. Clin J Am Soc Nephrol. 2011. PMID: 21088291 Free PMC article.
-
Increased microvolt T-wave alternans in children and adolescents with Eisenmenger syndrome.Anatol J Cardiol. 2018 May;19(5):303-310. doi: 10.14744/AnatolJCardiol.2018.60487. Epub 2018 Apr 10. Anatol J Cardiol. 2018. PMID: 29638226 Free PMC article.
-
Microvolt T-wave alternans physiological basis, methods of measurement, and clinical utility--consensus guideline by International Society for Holter and Noninvasive Electrocardiology.J Am Coll Cardiol. 2011 Sep 20;58(13):1309-24. doi: 10.1016/j.jacc.2011.06.029. J Am Coll Cardiol. 2011. PMID: 21920259 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources