Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Feb;42(2):137-46.
doi: 10.1016/s0010-9452(08)70337-x.

Diagnosing and phenotyping visual synaesthesia: a preliminary evaluation of the revised test of genuineness (TOG-R)

Affiliations

Diagnosing and phenotyping visual synaesthesia: a preliminary evaluation of the revised test of genuineness (TOG-R)

Julian E Asher et al. Cortex. 2006 Feb.

Abstract

Synaesthesia, a neurological condition affecting approximately .05% of the population, is characterised by anomalous sensory perception: a stimulus in one sensory modality triggers an automatic, instantaneous, consistent response in another modality (e.g., sound evokes colour) or in a different aspect of the same modality (e.g., black text evokes colour). As evidence was limited to case studies based on self-report, the existence of synaesthesia was regarded with scepticism until the development of the Test of Genuineness (TOG) in 1987, which measures the consistency of stimulus-response linkage: synaesthetes typically score between 70-90% range, whereas controls typically score between 20-38%. However, the TOG had only limited ability to quantify the characteristics of visual synaesthesia. In this study, the revised Test of Genuineness (TOG-R), utilising the Pantone-based Cambridge Synaesthesia Charts, was given to 26 synaesthetes and 23 controls. Results confirmed that the TOG-R is equally accurate in the diagnosis of synaesthesia; synaesthetes scored significantly (t47 = 16.01, p < .001) higher (mean = 71.3%, SEM = 1.4%) than controls (mean = 33%, SEM = 2.0%). The TOG-R provides greater precision in quantifying the closeness of colour matches and enables a more detailed analysis of visual synaesthesia. Synaesthetes were phenotyped into broad- and narrowband based on their overall responsiveness to auditory stimuli, with bandwidth determined primarily by responsiveness to non-word stimuli. They were further sub-phenotyped based on responses to sub-groups of stimuli into word-colour (WC) and music-colour (MC). Development of this instrument has important implications for the diagnosis and phenotyping of visual synaesthesia.

PubMed Disclaimer

Publication types

LinkOut - more resources