Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation
- PMID: 16684014
- DOI: 10.1111/j.1540-8167.2006.00425.x
Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation
Abstract
Introduction: No prior studies have reported the use of integrated electroanatomic mapping with preacquired magnetic resonance/computed tomographic (MR/CT) images to guide catheter ablation of atrial fibrillation (AF) in a series of patients.
Methods and results: Sixteen consecutive patients with drug-refractory AF underwent catheter ablation under the guidance of a three-dimensional (3D) electroanatomic mapping system (Carto, Biosense Webster, Inc., Diamond Bar, CA, USA). Gadolinium-enhanced MR (n = 8) or contrast-enhanced high-resolution CT (n = 8) imaging was performed within 1 day prior to the ablation procedures. Using a novel software package (CartoMerge, Biosense Webster, Inc.), the left atrium (LA) with pulmonary veins (PVs) was segmented and extracted for image registration. The segmented 3D MR/CT LA reconstruction was accurately registered to the real-time mapping space with a combination of landmark registration and surface registration. The registered 3D MR/CT LA reconstruction was successfully used to guide deployment of RF applications encircling the PVs. Upon completion of the circumferential lesions around the PVs, 32% of the PVs were electrically isolated. Guided by a circular mapping catheter, the remaining PVs were disconnected from the LA using a segmental approach. The distance between the surface of the registered 3D MR/CT LA reconstruction and multiple electroanatomic map points was 3.05 +/- 0.41 mm. No complications were observed.
Conclusions: Three-dimensional MR/CT images can be successfully extracted and registered to anatomically guided clinical AF ablations. The display of detailed and accurate anatomic information during the procedure enables tailored RF ablation to individual PV and LA anatomy.
Comment in
-
Three-dimensional image integration: a first experience with guidance of atrial fibrillation ablations.J Cardiovasc Electrophysiol. 2006 May;17(5):467-8. doi: 10.1111/j.1540-8167.2006.00449.x. J Cardiovasc Electrophysiol. 2006. PMID: 16684015 No abstract available.
Similar articles
-
Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system: validation of a registration method.Pacing Clin Electrophysiol. 2008 Mar;31(3):273-82. doi: 10.1111/j.1540-8159.2008.00986.x. Pacing Clin Electrophysiol. 2008. PMID: 18307621
-
[Efficacy of integrated three-dimensional electroanatomic mapping with preacquired magnetic resonance images guide catheter atrial fibrillation ablation].Zhonghua Xin Xue Guan Bing Za Zhi. 2007 Nov;35(11):1029-33. Zhonghua Xin Xue Guan Bing Za Zhi. 2007. PMID: 18269825 Chinese.
-
The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation.J Cardiovasc Electrophysiol. 2006 Oct;17(10):1093-101. doi: 10.1111/j.1540-8167.2006.00594.x. J Cardiovasc Electrophysiol. 2006. PMID: 16989651 Clinical Trial.
-
Image integration in catheter ablation of atrial fibrillation.Europace. 2008 Nov;10 Suppl 3:iii48-56. doi: 10.1093/europace/eun235. Europace. 2008. PMID: 18955399 Review.
-
Image integration in electroanatomic mapping.Herzschrittmacherther Elektrophysiol. 2007 Sep;18(3):122-30. doi: 10.1007/s00399-007-0571-z. Herzschrittmacherther Elektrophysiol. 2007. PMID: 17891488 Review.
Cited by
-
[Cardiac computed tomography and ablation of atrial fibrillation].Herzschrittmacherther Elektrophysiol. 2012 Dec;23(4):281-8. doi: 10.1007/s00399-012-0239-1. Epub 2012 Dec 5. Herzschrittmacherther Elektrophysiol. 2012. PMID: 23212602 Review. German.
-
Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy.Int J Comput Assist Radiol Surg. 2009 Mar;4(2):113-23. doi: 10.1007/s11548-008-0278-6. Epub 2008 Nov 15. Int J Comput Assist Radiol Surg. 2009. PMID: 20033609
-
Use of imaging techniques to guide catheter ablation procedures.Curr Cardiol Rep. 2010 Sep;12(5):374-81. doi: 10.1007/s11886-010-0132-7. Curr Cardiol Rep. 2010. PMID: 20607626 Review.
-
Time-resolved interventional cardiac C-arm cone-beam CT: an application of the PICCS algorithm.IEEE Trans Med Imaging. 2012 Apr;31(4):907-23. doi: 10.1109/TMI.2011.2172951. Epub 2011 Oct 20. IEEE Trans Med Imaging. 2012. PMID: 22027367 Free PMC article.
-
Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration.J Interv Card Electrophysiol. 2016 Aug;46(2):153-9. doi: 10.1007/s10840-016-0105-x. Epub 2016 Jan 27. J Interv Card Electrophysiol. 2016. PMID: 26814840 Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials