Adaptive spatio-temporal restoration for 4D fluorescence microscopic imaging
- PMID: 16685931
- DOI: 10.1007/11566465_110
Adaptive spatio-temporal restoration for 4D fluorescence microscopic imaging
Abstract
We present a spatio-temporal filtering method for significantly increasing the signal-to-noise ratio (SNR) in noisy fluorescence microscopic image sequences where small particles have to be tracked from frame to frame. Image sequence restoration is achieved using a statistical approach involving an appropriate on-line window geometry specification. We have applied this method to noisy synthetic and real microscopic image sequences where a large number of small fluorescently labeled vesicles are moving in regions close to the Golgi apparatus. The SNR is shown to be drastically improved and the enhanced vesicles can be segmented. This novel approach can be further exploited for biological studies where the dynamics of small objects of interest have to be analyzed in molecular and sub-cellular bio-imaging.
Similar articles
-
Segmenting and tracking fluorescent cells in dynamic 3-D microscopy with coupled active surfaces.IEEE Trans Image Process. 2005 Sep;14(9):1396-410. doi: 10.1109/tip.2005.852790. IEEE Trans Image Process. 2005. PMID: 16190474
-
Single quantum dot tracking based on perceptual grouping using minimal paths in a spatiotemporal volume.IEEE Trans Image Process. 2005 Sep;14(9):1384-95. doi: 10.1109/tip.2005.852794. IEEE Trans Image Process. 2005. PMID: 16190473
-
Cells tracking in a live zebrafish embryo.Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:1631-4. doi: 10.1109/IEMBS.2007.4352619. Annu Int Conf IEEE Eng Med Biol Soc. 2007. PMID: 18002285
-
From quantitative microscopy to automated image understanding.J Biomed Opt. 2004 Sep-Oct;9(5):893-912. doi: 10.1117/1.1779233. J Biomed Opt. 2004. PMID: 15447010 Free PMC article. Review.
-
Tracking movement in cell biology.Adv Biochem Eng Biotechnol. 2005;95:267-95. doi: 10.1007/b102218. Adv Biochem Eng Biotechnol. 2005. PMID: 16080272 Review.
Cited by
-
3D wavelet subbands mixing for image denoising.Int J Biomed Imaging. 2008;2008:590183. doi: 10.1155/2008/590183. Int J Biomed Imaging. 2008. PMID: 18431448 Free PMC article.
-
[Magnitude image-guided phase unwrapping algorithm of susceptibility weighted images].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017 Oct 1;34(5):721-729. doi: 10.7507/1001-5515.201611011. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2017. PMID: 29761958 Free PMC article. Chinese.
-
An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.IEEE Trans Med Imaging. 2008 Apr;27(4):425-41. doi: 10.1109/TMI.2007.906087. IEEE Trans Med Imaging. 2008. PMID: 18390341 Free PMC article.