Quantitative analysis of the effects of physiologic brain motion on point-resolved spectroscopy
- PMID: 16687544
- PMCID: PMC7975735
Quantitative analysis of the effects of physiologic brain motion on point-resolved spectroscopy
Abstract
Background and purpose: Although single-voxel proton MR spectroscopy is a noninvasive method that enables measurement of brain metabolite concentrations, it has been shown that physiologic brain motion causes inaccuracies in measurement of metabolite concentrations and increases the overall SD of the measurements when the stimulated echo acquisition mode (STEAM) is used. We tested the hypothesis that the point-resolved spectroscopy (PRESS) technique is less sensitive to physiologic brain motion than the STEAM technique.
Methods: In 10 healthy subjects, spectra were obtained from a voxel located in the left basal ganglia by using the PRESS sequence with cardiac gating and without water suppression to assess global phase change as a function of physiologic brain motion. This was accomplished by acquiring data at various time delays from the R wave throughout the cardiac cycle. Subsequently, spectra were obtained in 10 healthy subjects by using PRESS both without and with cardiac gating, and with water suppression, to determine whether brain motion resulted in a statistically significant difference in mean and SD of measured metabolite concentration.
Results: At various time delays from the R wave throughout the cardiac cycle, no significant global phase difference was noted in water signal intensity. In addition, when PRESS data were obtained both without and with cardiac gating (by using an optimal delay obtained from previously published data by using STEAM), no significant difference was seen in measured metabolite concentrations and SDs.
Conclusion: The PRESS technique is relatively insensitive to physiologic brain motion.
Figures
References
-
- Bergstrand G, Bergstrom M, Nordell B, et al. Cardiac gated MR imaging of the cerebrospinal fluid flow. J Comput Assist Tomogr 1985;9:1003–06 - PubMed
-
- Feinberg DA, Mark AS. Human brain motion and cerebrospinal fluid flow circulation demonstrated with MR velocity imaging. Radiology 1987;163:793–99 - PubMed
-
- Greitz D, Wirestam R, Franck A, et al. Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imaging: the Monro-Kellie doctrine revisited. Neuroradiology 1992;34:370–80 - PubMed
-
- Pattany PM, Phillips JJ, Chiu JC, et al. Motion artifact suppression technique (MAST) for MR imaging. J Comput Assist Tomogr 1987;2:369–77 - PubMed
-
- Felmlee JP, Ehrman RL. Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology 1987;164:559–64 - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources