Abstract
Although single dialyzer use and reuse by chemical reprocessing are both associated with some complications, there is no definitive advantage to either in this respect. Some complications occur mainly at the first use of a dialyzer: a new cellophane or cuprophane membrane may activate the complement system, or a noxious agent may be introduced to the dialyzer during production or generated during storage. These agents may not be completely removed during the routine rinsing procedure. The reuse of dialyzers is associated with environmental contamination, allergic reactions, residual chemical infusion (rebound release), inadequate concentration of disinfectants, and pyrogen reactions. Bleach used during reprocessing causes a progressive increase in dialyzer permeability to larger molecules, including albumin. Reprocessing methods without the use of bleach are associated with progressive decreases in membrane permeability, particularly to larger molecules. Most comparative studies have not shown differences in mortality between centers reusing and those not reusing dialyzers, however, the largest cluster of dialysis-related deaths occurred with single-use dialyzers due to the presence of perfluorohydrocarbon introduced during the manufacturing process and not completely removed during preparation of the dialyzers before the dialysis procedure. The cost savings associated with reuse is substantial, especially with more expensive, high-flux synthetic membrane dialyzers. With reuse, some dialysis centers can afford to utilize more efficient dialyzers that are more expensive; consequently they provide a higher dose of dialysis and reduce mortality. Some studies have shown minimally higher morbidity with chemical reuse, depending on the method. Waste disposal is definitely decreased with the reuse of dialyzers, thus environmental impacts are lessened, particularly if reprocessing is done by heat disinfection. It is safe to predict that dialyzer reuse in dialysis centers will continue because it also saves money for the providers. Saving both time for the patient and money for the provider were the main motivations to design a new machine for daily home hemodialysis. The machine, developed in the 1990s, cleans and heat disinfects the dialyzer and lines in situ so they do not need to be changed for a month. In contrast, reuse of dialyzers in home hemodialysis patients treated with other hemodialysis machines is becoming less popular and is almost extinct.
Similar articles
-
Dialyzer reuse-Part I: Historical perspective.Semin Dial. 2006 Jan-Feb;19(1):41-53. doi: 10.1111/j.1525-139X.2006.00118.x. Semin Dial. 2006. PMID: 16423181
-
National Kidney Foundation report on dialyzer reuse. Task Force on Reuse of Dialyzers, Council on Dialysis, National Kidney Foundation.Am J Kidney Dis. 1997 Dec;30(6):859-71. doi: 10.1016/s0272-6386(97)90096-2. Am J Kidney Dis. 1997. PMID: 9398135 Review.
-
Mortality risk by hemodialyzer reuse practice and dialyzer membrane characteristics: results from the usrds dialysis morbidity and mortality study.Am J Kidney Dis. 2001 Feb;37(2):276-86. doi: 10.1053/ajkd.2001.21290. Am J Kidney Dis. 2001. PMID: 11157367
-
Dialyzer reprocessing with peroxyacetic acid as sole cleansing and sterilizing agent.Acta Med Croatica. 1997;51(2):87-93. Acta Med Croatica. 1997. PMID: 9204593
-
The technology of dialyzer reuse.Semin Nephrol. 1997 Jul;17(4):321-30. Semin Nephrol. 1997. PMID: 9241717 Review.
Cited by
-
Measurement accuracy of total cell volume by automated dialyzer reprocessing: A prospective cohort study.Ann Med Surg (Lond). 2017 May 3;18:16-23. doi: 10.1016/j.amsu.2017.04.019. eCollection 2017 Jun. Ann Med Surg (Lond). 2017. PMID: 28515906 Free PMC article.
-
Green Dialysis From the Indian Perspective: A Systematic Review.Cureus. 2024 Jun 21;16(6):e62876. doi: 10.7759/cureus.62876. eCollection 2024 Jun. Cureus. 2024. PMID: 39040742 Free PMC article. Review.
-
Endotoxin-Retentive Filters for the Online Preparation of Ultrapure Dialysis Fluid and Non-Pyrogenic Substitution Fluid: A Critical Review and Reference Guide.Membranes (Basel). 2025 Feb 5;15(2):51. doi: 10.3390/membranes15020051. Membranes (Basel). 2025. PMID: 39997677 Free PMC article. Review.
-