Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Controlled Clinical Trial
. 2006 Sep;101(3):707-14.
doi: 10.1152/japplphysiol.00154.2006. Epub 2006 May 11.

Influence of acute plasma volume expansion on VO2 kinetics, VO2 peak, and performance during high-intensity cycle exercise

Affiliations
Free article
Controlled Clinical Trial

Influence of acute plasma volume expansion on VO2 kinetics, VO2 peak, and performance during high-intensity cycle exercise

Nicolas J A Berger et al. J Appl Physiol (1985). 2006 Sep.
Free article

Abstract

The purpose of this study was to examine the influence of acute plasma volume expansion (APVE) on oxygen uptake (V(O2)) kinetics, V(O2peak), and time to exhaustion during severe-intensity exercise. Eight recreationally active men performed "step" cycle ergometer exercise tests at a work rate requiring 70% of the difference between the gas-exchange threshold and V(O2max) on three occasions: twice as a "control" (Con) and once after intravenous infusion of a plasma volume expander (Gelofusine; 7 ml/kg body mass). Pulmonary gas exchange was measured breath by breath. APVE resulted in a significant reduction in hemoglobin concentration (preinfusion: 16.0 +/- 1.0 vs. postinfusion: 14.7 +/- 0.8 g/dl; P < 0.001) and hematocrit (preinfusion: 44 +/- 2 vs. postinfusion: 41 +/- 3%; P < 0.01). Despite this reduction in arterial O(2) content, APVE had no effect on V(O2) kinetics (phase II time constant, Con: 33 +/- 15 vs. APVE: 34 +/- 12 s; P = 0.74), and actually resulted in an increased V(O2peak) (Con: 3.90 +/- 0.56 vs. APVE: 4.12 +/- 0.55 l/min; P = 0.006) and time to exhaustion (Con: 365 +/- 58 vs. APVE: 424 +/- 64 s; P = 0.04). The maximum O(2) pulse was also enhanced by the treatment (Con: 21.3 +/- 3.4 vs. APVE: 22.7 +/- 3.4 ml/beat; P = 0.04). In conclusion, APVE does not alter V(O2) kinetics but enhances V(O2peak) and exercise tolerance during high-intensity cycle exercise in young recreationally active subjects.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources