Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 May-Jun;13(3):216-21.
doi: 10.1016/j.jmig.2006.01.005.

Novel application of polypropylene sling: transvaginal cervicoisthmic cerclage in women with high risk of preterm delivery

Affiliations

Novel application of polypropylene sling: transvaginal cervicoisthmic cerclage in women with high risk of preterm delivery

Xavier Deffieux et al. J Minim Invasive Gynecol. 2006 May-Jun.

Abstract

Study objective: To describe a novel technique of transvaginal cervicoisthmic cerclage with a polypropylene sling in prevention of preterm labor in pregnant women at high risk.

Design: Retrospective study (Canadian Task Force classification: III).

Setting: University hospital (department of obstetrics and gynecology).

Patients: Twenty-one women showing symptoms of high risk of preterm delivery: histories of pregnancy losses in the second trimester and prior failure of MacDonald's cerclage or absent portio vaginalis of the cervix. The median age of the patients was 32.8 years (range 22-39 years).

Interventions: Cerclage was performed between 12 and 16 weeks' gestation. A polypropylene tape was placed at the cervicoisthmic junction by vaginal route. Caesarean delivery was systematically performed in all patients because the cerclage was considered to be definitive.

Measurements and main results: No intraoperative complications occurred. The mean operating time was 36 +/- 6 minutes (range 30-45 minutes). The mean length of stay was 1.4 +/- 0.5 days. Mean gestational age and birth weight at delivery were respectively 37.1 +/- 1.8 weeks (CI 95%: 36.4-37.9) and 2850 +/- 745 g (CI 95%: 2531-3168). The preterm birth rate was 19% (4/21). One neonatal death occurred after amniotic fluid infection at 34 weeks. Birth at less than 32 weeks occurred in one patient (4%).

Conclusion: Transvaginal cervicoisthmic cerclage with polypropylene sling may be considered as an effective and minimally invasive alternative to the transabdominal cervicoisthmic cerclage in women presenting with high risk of preterm delivery.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources