The effect of MR contrast medium dose on pituitary gland enhancement, microlesion enhancement and pituitary gland-to-lesion contrast conspicuity
- PMID: 16699802
- DOI: 10.1007/s00234-006-0085-0
The effect of MR contrast medium dose on pituitary gland enhancement, microlesion enhancement and pituitary gland-to-lesion contrast conspicuity
Abstract
Introduction: The purpose of this study was to compare the differences in gland enhancement, microlesion enhancement and gland-lesion contrast ratio in patient groups in which half-dose (HD), standard-dose (SD) and double-dose (DD) contrast medium was used in pituitary MR imaging.
Methods: Pituitary gland enhancement and microlesion enhancement were measured and gland-lesion contrast ratios were calculated in 18 patients receiving HD (0.05 mmol/kg), 9 receiving SD (0.1 mmol/kg) and 13 receiving DD (0.2 mmol/kg) contrast medium. Gland enhancement and microlesion enhancement over baseline were determined employing DICOM region of interest measurements and compared after normalization to temporal lobe white matter. Contrast ratios and differences were also calculated and compared.
Results: Gland enhancement and lesion enhancement were greater with larger contrast medium doses (gland: HD 50%, SD 99%, DD 132%; microlesion: HD 19%, SD 54%, DD 86%). The gland-lesion contrast ratios were similar with the three doses (25.6%), reflecting expected similar fractional contrast medium distributions in spite of different doses. The signal difference between gland and microlesion, therefore, was a fixed percentage of gland enhancement (DeltaS approximately 26%) with greater signal differences with larger contrast medium doses.
Conclusion: Greater gland-to-lesion signal differences with larger contrast medium doses would likely improve pituitary microlesion visualization and margin characterization aiding in microlesion detection as well as preoperative planning.
Similar articles
-
Comparison of Low-Dose Higher-Relaxivity and Standard-Dose Lower-Relaxivity Contrast Media for Delayed-Enhancement MRI: A Blinded Randomized Crossover Study.AJR Am J Roentgenol. 2015 Sep;205(3):533-9. doi: 10.2214/AJR.14.13749. AJR Am J Roentgenol. 2015. PMID: 26295638 Clinical Trial.
-
Effect of dose and field strength on enhancement with paramagnetic contrast media.AJNR Am J Neuroradiol. 1994 Nov;15(10):1849-52. AJNR Am J Neuroradiol. 1994. PMID: 7863934 Free PMC article. Clinical Trial.
-
Low-field interventional MRI in neurosurgery: finding the right dose of contrast medium.Neuroradiology. 2001 Mar;43(3):254-8. doi: 10.1007/pl00006047. Neuroradiology. 2001. PMID: 11305762 Clinical Trial.
-
Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children.Pediatr Radiol. 2005 May;35(5):501-10. doi: 10.1007/s00247-004-1392-4. Epub 2005 Jan 28. Pediatr Radiol. 2005. PMID: 15678342 Clinical Trial.
-
Contrast use at low field: a review.Top Magn Reson Imaging. 2003 Oct;14(5):360-4. doi: 10.1097/00002142-200310000-00002. Top Magn Reson Imaging. 2003. PMID: 14625464 Review.
Cited by
-
Pituitary magnetic resonance imaging in Cushing's disease.Endocrine. 2017 Mar;55(3):691-696. doi: 10.1007/s12020-016-1038-y. Epub 2016 Jul 19. Endocrine. 2017. PMID: 27435590 Review.
-
Application of Contrast-Enhanced 3-Dimensional T2-Weighted Volume Isotropic Turbo Spin Echo Acquisition Sequence in the Diagnosis of Prolactin-Secreting Pituitary Microadenomas.J Comput Assist Tomogr. 2022 Jan-Feb 01;46(1):116-123. doi: 10.1097/RCT.0000000000001237. J Comput Assist Tomogr. 2022. PMID: 35099143 Free PMC article.
-
Pituitary magnetic resonance imaging vs. bilateral inferior petrosal sinus sampling: comparison between non-invasive and invasive diagnostic techniques for Cushing's disease-a narrative review.Gland Surg. 2020 Dec;9(6):2260-2268. doi: 10.21037/gs-20-654. Gland Surg. 2020. PMID: 33447578 Free PMC article. Review.
-
7T MRI for Cushing Disease: A Single-Institution Experience and Literature Review.AJNR Am J Neuroradiol. 2024 Jul 8;45(7):971-976. doi: 10.3174/ajnr.A8209. AJNR Am J Neuroradiol. 2024. PMID: 38365424 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical