Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
- PMID: 16707118
- DOI: 10.1016/j.cca.2006.03.034
Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
Abstract
Background: Serum steroid assays play an important role in the clinical evaluation of a number of common endocrine disorders. Among various assays, tandem mass spectrometry (MS/MS) has being increasingly applied in clinical laboratories for its high sensitivity, specificity, and simultaneous multi-analyte quantitation capability. Our first generation isotope dilution steroid profile assay by HPLC-tandem MS/MS with a C-18 column allowed for the measurement of 9 steroids in 18 min employing a sample volume of 760 ul serum. We describe our second generation steroid profile assay which allows for the quantitation of 12 steroids simultaneously employing HPLC-MS/MS and isotope dilution tandem MS in 11 min. This method requires a sample volume of 200 microl.
Methods: An API-5000 triple-quadrupole mass spectrometer (Sciex, Concord, Canada) coupled with the PhotoSpray source and Shimadzu HPLC system (Shimadzu Scientific Instruments, Columbia, MD) was used employing isotope dilution with deuterium labeled internal standard (IS) for each analyte. Two hundred microliters of serum were deproteinized by adding 300 microl of acetonitrile containing internal standards. After centrifugation, 450 microl of supernatant were diluted with 900 microl of water and 1000 microl aliquot were injected onto a C-8 column. After a 3 min wash the valve was activated to initiate the gradient elution program which eluted the steroids. Quantitation by MRM analysis was performed both in positive ion mode for 11 analytes and in negative ion mode for aldosterone. Within-day and between-day precision, reliability and accuracy of this method were assessed by correlation with other MS/MS and immunoassay methods and by recovery study.
Results: Within-day CVs were <11.5% for all analytes tested and between-day CVs ranged from 3.5% to 12.2%. The results of the comparison study yield r values ranging between 0.908 and 0.999. Recovery ranged from 90% to 110%.
Conclusions: This method can simultaneously measure 12 steroids in serum within 11 min with minimal sample preparation. It can be routinely employed in a clinical environment and is attractive because of its simplicity in sample processing and high throughput.
Similar articles
-
Determination of levetiracetam in human plasma/serum/saliva by liquid chromatography-electrospray tandem mass spectrometry.Clin Chim Acta. 2007 Jan;375(1-2):115-8. doi: 10.1016/j.cca.2006.06.022. Epub 2006 Jun 27. Clin Chim Acta. 2007. PMID: 16914128
-
Simultaneous quantification of GM1 and GM2 gangliosides by isotope dilution tandem mass spectrometry.Clin Biochem. 2008 Apr;41(6):413-7. doi: 10.1016/j.clinbiochem.2007.12.026. Epub 2008 Jan 17. Clin Biochem. 2008. PMID: 18241673
-
Rapid measurement of plasma acylcarnitines by liquid chromatography-tandem mass spectrometry without derivatization.Clin Chim Acta. 2005 Aug;358(1-2):104-12. doi: 10.1016/j.cccn.2005.02.011. Epub 2005 Apr 9. Clin Chim Acta. 2005. PMID: 16018880
-
Isotope ratio determination in boron analysis.Biol Trace Elem Res. 1998 Winter;66(1-3):39-53. doi: 10.1007/BF02783124. Biol Trace Elem Res. 1998. PMID: 10050906 Review.
-
Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry.Clin Biochem. 2005 Apr;38(4):328-34. doi: 10.1016/j.clinbiochem.2004.11.007. Clin Biochem. 2005. PMID: 15766734 Review.
Cited by
-
Revisiting hyper- and hypo-androgenism by tandem mass spectrometry.Rev Endocr Metab Disord. 2013 Jun;14(2):185-205. doi: 10.1007/s11154-013-9243-y. Rev Endocr Metab Disord. 2013. PMID: 23619762
-
An improved micro-method for the measurement of steroid profiles by APPI-LC-MS/MS and its use in assessing diurnal effects on steroid concentrations and optimizing the diagnosis and treatment of adrenal insufficiency and CAH.J Steroid Biochem Mol Biol. 2016 Sep;162:110-6. doi: 10.1016/j.jsbmb.2015.12.024. Epub 2015 Dec 22. J Steroid Biochem Mol Biol. 2016. PMID: 26721696 Free PMC article.
-
Correlations of free thyroid hormones measured by tandem mass spectrometry and immunoassay with thyroid-stimulating hormone across 4 patient populations.Clin Chem. 2009 Jul;55(7):1380-8. doi: 10.1373/clinchem.2008.118752. Epub 2009 May 21. Clin Chem. 2009. PMID: 19460839 Free PMC article.
-
Pediatric reference intervals for aldosterone, 17alpha-hydroxyprogesterone, dehydroepiandrosterone, testosterone and 25-hydroxy vitamin D3 using tandem mass spectrometry.Clin Biochem. 2009 Jun;42(9):823-7. doi: 10.1016/j.clinbiochem.2009.01.015. Epub 2009 Feb 6. Clin Biochem. 2009. PMID: 19318024 Free PMC article.
-
Tandem mass spectrometry as a novel tool for elucidating pituitary-thyroid relationships.Thyroid. 2008 Dec;18(12):1303-11. doi: 10.1089/thy.2008.0155. Thyroid. 2008. PMID: 19067639 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources