Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Aug;48(8):528-32.
doi: 10.1007/s00234-006-0093-0. Epub 2006 May 18.

Modified technique to create morphologically reproducible elastase-induced aneurysms in rabbits

Affiliations

Modified technique to create morphologically reproducible elastase-induced aneurysms in rabbits

Yong Hong Ding et al. Neuroradiology. 2006 Aug.

Abstract

Introduction: The purpose of this study was to create morphologically reproducible elastase-induced model aneurysms in rabbits.

Methods: We created 120 elastase-induced aneurysms in rabbits using two different methods: the standard technique (group 1, n=62) and a modified technique (group 2, n=58). In the standard technique a small cutdown with a focal area of exposure of the mid-right common carotid artery (RCCA) was employed, while in the modified technique the RCCA was completely exposed to its origin. We measured aneurysm sizes (neck diameter, width and height) in the two groups. The aneurysm sizes were compared between the two groups using Student's t test, and the standard deviations of the aneurysm sizes were compared between the groups using the F test.

Results: The mean aneurysm neck size, width and height in group 1 were 3.4+/-1.2 mm, 3.8+/-1.0 mm and 8.0+/-1.7 mm, respectively, and in group 2, were 3.2+/-0.9 mm, 3.7+/-0.6 mm and 9.1+/-1.8 mm, respectively. The differences in mean aneurysm neck and width between the two groups were not significant (P>0.05). However, there were significant differences in the standard deviation of these two parameters between the two groups (P<0.05 and P<0.01, respectively). The mean aneurysm height in group 2 was larger than in group 1 (P<0.001), but no significant difference in the standard deviation of this parameter between the two groups was found (P>0.05).

Conclusion: The results indicate that more consistent aneurysm diameters can be created using the modified technique.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Neuroradiology. 2003 Jul;45(7):423-9 - PubMed
    1. Radiology. 1999 Oct;213(1):223-8 - PubMed
    1. Pathology. 1997 Nov;29(4):374-9 - PubMed
    1. AJR Am J Roentgenol. 2003 Sep;181(3):739-41 - PubMed
    1. AJNR Am J Neuroradiol. 1992 Jul-Aug;13(4):1089-95 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources