Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1991 Jan 26;337(8735):196-200.
doi: 10.1016/0140-6736(91)92158-x.

Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism

Affiliations
Comparative Study

Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism

H Bounameaux et al. Lancet. .

Abstract

The potential of plasma measurement of D-dimer (DD), a specific derivative of crosslinked fibrin, for diagnosis or exclusion of pulmonary embolism was investigated in a prospective series of 171 consecutive patients who attended an emergency department with suspected pulmonary embolism. The diagnosis was made or excluded by means of a clinical decision-making process which included clinical evaluation, ventilation-perfusion (VQ) lung scan, and, as indicated, pulmonary angiography, venography, or non-invasive examination of the leg veins. Pulmonary embolism was diagnosed by this process in 55 (32%) of 170 patients with sufficient data. All but 1 of these 55 patients had a DD concentration of 500 micrograms/l or above. The sensitivity and specificity of this cutoff concentration for the presence of pulmonary embolism were 98% and 39%, respectively, which give positive and negative predictive values of 44% and 98%. Among the 115 patients (68%) who had inconclusive VQ scans, 31 were diagnosed as having pulmonary embolism. 29 of the remaining 84 patients without pulmonary embolism had DD concentrations below 500 micrograms/l, which means that further diagnostic procedures could have been avoided in a quarter of the patients with inconclusive VQ scans. The sensitivity of the plasma measurement of DD remained high even 3 and 7 days after presentation (96% and 93%). Plasma measurement of DD therefore has a definite place in the diagnostic procedure for suspected acute pulmonary embolism in attenders at emergency departments: a concentration below 500 micrograms/l rules out the diagnosis.

PubMed Disclaimer

Comment in

Publication types

Substances

LinkOut - more resources