Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Mar 15;848(1):88-96.
doi: 10.1016/j.jchromb.2006.03.065. Epub 2006 May 23.

Characterisation of an industrial affinity process used in the manufacturing of digoxin-specific polyclonal Fab fragments

Affiliations

Characterisation of an industrial affinity process used in the manufacturing of digoxin-specific polyclonal Fab fragments

Pranavan Thillaivinayagalingam et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

This paper describes the effect of several variables on the affinity process for the production of the FDA approved biotherapeutic product Digoxin Immune Fab (Ovine) (DigiFab, Protherics Inc., TN, USA). The study considers the effects of column re-use on matrix capacity and on the subsequent recovery of the antibody product, and the impact of varying column loading on matrix performance. The methodology used could be equally applied to assess the feasibility of using an affinity matrix for commercial scale purification of alternative antibody derived biotherapeutics. The capacity and specific Fab recovery were calculated through 24h equilibrium and mass balance studies. Results were assessed against data obtained through confocal scanning laser microscopy. Scale-down experiments produced specific Fab recoveries and purities that were comparable with those at production scale. The matrix capacity was found to be 45+/-15 mg of Fab/ml of matrix. Through the use of fluorescent DigiFab and confocal scanning techniques, Fab uptake onto single affinity bead was evaluated. Average intensity values calculated for each sample provided direct real-time, measure of Fab binding and matrix capacity. The results suggest that the affinity matrix had a limited reuse life as a drop in recovery is observed following the completion of a small number of process cycles (30% after three runs). The findings support that which is seen at the current manufacturing scale, where the affinity column is used for a limited number of runs. Results from this study can be used as a basis for future optimisation of this purification process.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

Substances

LinkOut - more resources