Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise
- PMID: 16729377
- DOI: 10.1055/s-2005-865666
Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise
Abstract
The purpose of this study was to test the accuracy of a new portable spirometric-telemetric device (Oxycon Mobile) over a wide range of exercise intensities against an accurate stationary apparatus (Oxycon Pro). Therefore, fifteen endurance-trained subjects (VO2peak: 58.8 +/- 5.2 ml x min(-1) x kg(-1)) performed an incremental as well as an endurance exercise test on two different occasions. Gas exchange variables were measured by the two ergospirometric devices simultaneously. For this purpose, a special face mask was designed which allowed respiratory gas sampling with both devices at exactly the same time. Compared to the Oxycon Pro as an accurate reference system, the Oxycon Mobile showed significantly lower values for VO2 at 200 and 250 W during the incremental exercise test. For VCO2 no significant differences were found although the Oxycon Mobile seemed to systematically measure higher values. With regard to RER the Oxycon Mobile showed significantly higher values at all workloads tested. We therefore dissuade from comparing gas exchange variables collected by the Oxycon Mobile with data measured under laboratory conditions by an accurate reference system like the Oxycon Pro. Furthermore, the extrapolation of information about substrate utilization during different exercise durations and intensities from data measured by the Oxycon Mobile seems inappropriate.
Similar articles
-
Validity and reliability of three commercially available breath-by-breath respiratory systems.Eur J Appl Physiol. 2002 Mar;86(5):435-41. doi: 10.1007/s00421-001-0572-2. Epub 2002 Feb 5. Eur J Appl Physiol. 2002. PMID: 11882930
-
Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer.Br J Sports Med. 2003;37(5):445-7. doi: 10.1136/bjsm.37.5.445. Br J Sports Med. 2003. PMID: 14514539 Free PMC article.
-
Validation of a computerized metabolic measurement system (Oxycon-Pro) during low and high intensity exercise.Int J Sports Med. 2001 May;22(4):291-4. doi: 10.1055/s-2001-14342. Int J Sports Med. 2001. PMID: 11414673
-
The validity of the telemetric system CORTEX X1 in the ventilatory and gas exchange measurement during exercise.Int J Sports Med. 1997 Aug;18(6):454-7. doi: 10.1055/s-2007-972663. Int J Sports Med. 1997. PMID: 9351692 Clinical Trial.
-
Portable open-circuit spirometry systems.J Sports Med Phys Fitness. 2017 Mar;57(3):227-237. doi: 10.23736/S0022-4707.16.06049-7. Epub 2016 Feb 10. J Sports Med Phys Fitness. 2017. PMID: 26861831 Review.
Cited by
-
Does the incremental shuttle walk test require maximal effort in young obese women?Braz J Med Biol Res. 2016 Jul 11;49(8):e5229. doi: 10.1590/1414-431X20165229. Braz J Med Biol Res. 2016. PMID: 27409333 Free PMC article.
-
Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.Eur J Appl Physiol. 2012 Aug;112(8):2785-815. doi: 10.1007/s00421-011-2268-6. Epub 2011 Dec 11. Eur J Appl Physiol. 2012. PMID: 22160180 Review.
-
Effectiveness of Energy Conservation Techniques in Patients with COPD.Respiration. 2020;99(5):409-416. doi: 10.1159/000506816. Epub 2020 Apr 9. Respiration. 2020. PMID: 32272478 Free PMC article.
-
Classical experiments in whole-body metabolism: open-circuit respirometry-diluted flow chamber, hood, or facemask systems.Eur J Appl Physiol. 2018 Jan;118(1):33-49. doi: 10.1007/s00421-017-3735-5. Epub 2017 Oct 27. Eur J Appl Physiol. 2018. PMID: 29080000 Free PMC article. Review.
-
Validity and reproducibility of VO2 max testing in a respiration chamber.Scand J Med Sci Sports. 2021 Jun;31(6):1259-1267. doi: 10.1111/sms.13944. Epub 2021 Mar 10. Scand J Med Sci Sports. 2021. PMID: 33638918 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous