Dosimetry of densely ionising radiation with three LiF phosphors for space applications
- PMID: 16731689
- DOI: 10.1093/rpd/nci674
Dosimetry of densely ionising radiation with three LiF phosphors for space applications
Abstract
A new method of thermoluminescence dosimetry of densely ionising radiation based on the ratio of different efficiency-LET functions of three thermoluminescent detectors (TLDs) has been developed. The applied TLD types are: MTS-7 ((7)LiF:Mg,Ti), MCP-7 ((7)LiF:Mg,Cu,P) and MTT-7 (a newly developed (7)LiF:Mg,Ti with modified activator composition and increased response to high-LET radiation). The tests of this method, performed with high-energy ion beams at the HIMAC accelerator within the ICCHIBAN project, proved that good agreement with the true dose values may be achieved even in very complicated mixed fields. The proposed method will be applied for analysis of several thousand TLDs used for the determination of organ doses in an anthropomorphic phantom orbiting outside the International Space Station within the MATROSHKA experiment.
Similar articles
-
Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.Radiat Prot Dosimetry. 2007;125(1-4):258-60. doi: 10.1093/rpd/ncl119. Epub 2006 Sep 15. Radiat Prot Dosimetry. 2007. PMID: 16980318
-
Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.Radiat Prot Dosimetry. 2005;115(1-4):334-6. doi: 10.1093/rpd/nci166. Radiat Prot Dosimetry. 2005. PMID: 16381741
-
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.Radiat Prot Dosimetry. 2006;119(1-4):248-54. doi: 10.1093/rpd/nci692. Epub 2006 Jul 11. Radiat Prot Dosimetry. 2006. PMID: 16835277 Review.
-
Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors.Radiat Prot Dosimetry. 2006;120(1-4):433-7. doi: 10.1093/rpd/nci652. Epub 2006 Apr 27. Radiat Prot Dosimetry. 2006. PMID: 16644947
-
Thermoluminescent detectors applied in individual monitoring of radiation workers in Europe--a review based on the EURADOS questionnaire.Radiat Prot Dosimetry. 2006;120(1-4):298-302. doi: 10.1093/rpd/nci538. Epub 2006 Mar 31. Radiat Prot Dosimetry. 2006. PMID: 16581929 Review.
Cited by
-
Tests of shielding effectiveness of Kevlar and Nextel onboard the International Space Station and the Foton-M3 capsule.Radiat Environ Biophys. 2010 Aug;49(3):359-63. doi: 10.1007/s00411-010-0283-3. Epub 2010 Apr 3. Radiat Environ Biophys. 2010. PMID: 20364264
-
Out-of-Field Doses Produced by a Proton Scanning Beam Inside Pediatric Anthropomorphic Phantoms and Their Comparison With Different Photon Modalities.Front Oncol. 2022 Jul 22;12:904563. doi: 10.3389/fonc.2022.904563. eCollection 2022. Front Oncol. 2022. PMID: 35957900 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous