Contrast-enhanced ultrasonography to detect liver metastases : a prospective trial to compare transcutaneous unenhanced and contrast-enhanced ultrasonography in patients undergoing laparotomy

Affiliations
Clinical Trial

Contrast-enhanced ultrasonography to detect liver metastases : a prospective trial to compare transcutaneous unenhanced and contrast-enhanced ultrasonography in patients undergoing laparotomy

R Konopke et al. Int J Colorectal Dis. 2007 Feb.

Abstract

Background/aims: The advent of contrast-enhanced ultrasound (CEUS) has called into question the efficacy of standard ultrasonographic techniques. In this study, we evaluated B-mode and color-duplex imaging and CEUS in the detection of liver metastases, using intraoperative and histological findings as a reference.

Materials and methods: Before laparotomy, 108 patients suspected of having liver metastases were prospectively examined with B-mode and color-duplex imaging, followed by contrast-enhanced ultrasound (2.4 ml SonoVue). Patients with unresectable tumors (n=8) were excluded from the analysis. The sonographic diagnosis in the remaining 100 patients was compared to the intraoperative and histological findings.

Results/findings: CEUS improved the sensitivity for detecting liver lesions from 56.3% (B-mode) to 83.8% (CEUS) (p=0.004). In particular, the contrast agent led to an improvement in ultrasonographic detection in the following cases: nodular metastases smaller than one centimeter; after adjuvant chemotherapy; for tumors near the surface of the liver; and for lesions situated around the ligamentum teres.

Interpretation/conclusions: CEUS provides significant improvement in the detection of liver metastases, and should therefore, be performed routinely in the surveillance of cancer patients.