Multicenter Study
. 2006 Jun 1;354(22):2317-27.
doi: 10.1056/NEJMoa052367.

Multidetector computed tomography for acute pulmonary embolism

Affiliations
Free article
Multicenter Study

Multidetector computed tomography for acute pulmonary embolism

Paul D Stein et al. N Engl J Med. .
Free article

Abstract

Background: The accuracy of multidetector computed tomographic angiography (CTA) for the diagnosis of acute pulmonary embolism has not been determined conclusively.

Methods: The Prospective Investigation of Pulmonary Embolism Diagnosis II trial was a prospective, multicenter investigation of the accuracy of multidetector CTA alone and combined with venous-phase imaging (CTA-CTV) for the diagnosis of acute pulmonary embolism. We used a composite reference test to confirm or rule out the diagnosis of pulmonary embolism.

Results: Among 824 patients with a reference diagnosis and a completed CT study, CTA was inconclusive in 51 because of poor image quality. Excluding such inconclusive studies, the sensitivity of CTA was 83 percent and the specificity was 96 percent. Positive predictive values were 96 percent with a concordantly high or low probability on clinical assessment, 92 percent with an intermediate probability on clinical assessment, and nondiagnostic if clinical probability was discordant. CTA-CTV was inconclusive in 87 of 824 patients because the image quality of either CTA or CTV was poor. The sensitivity of CTA-CTV for pulmonary embolism was 90 percent, and specificity was 95 percent. CTA-CTV was also nondiagnostic with a discordant clinical probability.

Conclusions: In patients with suspected pulmonary embolism, multidetector CTA-CTV has a higher diagnostic sensitivity than does CTA alone, with similar specificity. The predictive value of either CTA or CTA-CTV is high with a concordant clinical assessment, but additional testing is necessary when the clinical probability is inconsistent with the imaging results.

PubMed Disclaimer

Comment in

Publication types