Adaptation of pulse oximetry for fetal monitoring during labour
- PMID: 1674071
- DOI: 10.1016/0140-6736(91)92928-u
Adaptation of pulse oximetry for fetal monitoring during labour
Abstract
Application of pulse oximetry to intrapartum monitoring was investigated in 105 women. No adequate reading could be obtained in 44 cases. Two major sources of artifact, related to probe apposition and signal processing, were identified and excluded. The average arterial oxygen saturation from the fetal scalp was 82% (SD 6%), which is higher than has been inferred from pO2 levels. Readings below 60% or the development of an unstable baseline suggest the presence of substantial hypoxia and acidosis.
Comment in
-
Effect of oxytocin on fetal brain oxygenation during labour.Lancet. 1991 Jul 27;338(8761):254-5. doi: 10.1016/0140-6736(91)90396-7. Lancet. 1991. PMID: 1676807 No abstract available.
Similar articles
-
Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour.Acta Biomed. 2004;75 Suppl 1:45-52. Acta Biomed. 2004. PMID: 15301290
-
Fetal pulse oximetry during labor of 62 patients.Fetal Diagn Ther. 1996 Jan-Feb;11(1):37-45. doi: 10.1159/000264277. Fetal Diagn Ther. 1996. PMID: 8719720
-
The prediction of fetal acidosis by means of intrapartum fetal pulse oximetry.Am J Obstet Gynecol. 1999 Jan;180(1 Pt 1):73-81. doi: 10.1016/s0002-9378(99)70153-5. Am J Obstet Gynecol. 1999. PMID: 9914582
-
Fetal pulse oximetry: a new method of monitoring the fetus.Aust N Z J Obstet Gynaecol. 1994 Aug;34(4):428-32. doi: 10.1111/j.1479-828x.1994.tb01263.x. Aust N Z J Obstet Gynaecol. 1994. PMID: 7848233 Review.
-
Intrapartum fetal pulse oximetry. Part I: Principles and technical issues.Obstet Gynecol Surv. 2000 Mar;55(3):163-72. doi: 10.1097/00006254-200003000-00025. Obstet Gynecol Surv. 2000. PMID: 10713982 Review.
Cited by
-
Limitations of forehead pulse oximetry.J Clin Monit. 1995 Jul;11(4):253-6. doi: 10.1007/BF01617520. J Clin Monit. 1995. PMID: 7561999
-
Reflectance pulse oximetry at the forehead of newborns: the influence of varying pressure on the probe.J Clin Monit. 1996 Nov;12(6):421-8. doi: 10.1007/BF02199702. J Clin Monit. 1996. PMID: 8982906
-
Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability.J Clin Monit. 1996 May;12(3):225-30. doi: 10.1007/BF00857643. J Clin Monit. 1996. PMID: 8823646
-
Reflectance pulse oximetry at the forehead improves by pressure on the probe.J Clin Monit. 1995 Jul;11(4):237-44. doi: 10.1007/BF01617518. J Clin Monit. 1995. PMID: 7561997
-
Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.Front Physiol. 2020 Jan 14;10:1563. doi: 10.3389/fphys.2019.01563. eCollection 2019. Front Physiol. 2020. PMID: 32009976 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical