Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2006 Jun 6;47(11):2152-60.
doi: 10.1016/j.jacc.2005.10.078.

A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis: results of the Restenosis Intrastent: Balloon Angioplasty Versus Elective Sirolimus-Eluting Stenting (RIBS-II) trial

Affiliations
Randomized Controlled Trial

A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis: results of the Restenosis Intrastent: Balloon Angioplasty Versus Elective Sirolimus-Eluting Stenting (RIBS-II) trial

Fernando Alfonso et al. J Am Coll Cardiol. .

Abstract

Objectives: We sought to assess the effectiveness of sirolimus-eluting stents (SES) in patients with in-stent restenosis (ISR).

Background: Treatment of patients with ISR remains a challenge.

Methods: The Restenosis Intrastent: Balloon Angioplasty Versus Elective Sirolimus-Eluting Stenting (RIBS-II) study is a multicenter randomized trial conducted in 150 patients with ISR (76 allocated to SES and 74 to balloon angioplasty [BA]). The primary end point was recurrent restenosis rate at nine months. Secondary end points included prespecified subgroup analysis, lumen volume on intravascular ultrasound (IVUS), and a composite of major clinical events at one year.

Results: Angiographic success was obtained in all patients. At 9-month angiographic follow-up (96% of eligible patients) minimal lumen diameter was larger (2.52 mm [interquartile range (IQR) 2.09 to 2.81] vs. 1.54 mm [IQR 0.91 to 2.05]; p < 0.001) and recurrent restenosis rate was lower (11% vs. 39%; p < 0.001) in the SES group. Prespecified subgroup analyses were consistent with the main outcome measure. Lumen volume on IVUS at 9 months was also larger (279 mm3 [IQR 227 to 300] vs. 197 mm3 [IQR 177 to 230]; p < 0.001) in the SES group. At one-year clinical follow-up (100% of patients), the event-free survival (freedom from death, myocardial infarction, and target vessel revascularization) was significantly improved in the SES group (88% vs. 69%; p < 0.004) as the result of a lower requirement for target vessel revascularization (11% vs. 30%; p < 0.003).

Conclusions: In patients with ISR, the use of SES provides superior long-term clinical, angiographic, and IVUS outcome than BA treatment.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources