Evaluation of a macrofoam swab protocol for the recovery of Bacillus anthracis spores from a steel surface
- PMID: 16751562
- PMCID: PMC1489631
- DOI: 10.1128/AEM.02923-05
Evaluation of a macrofoam swab protocol for the recovery of Bacillus anthracis spores from a steel surface
Abstract
A protocol to recover Bacillus anthracis spores from a steel surface using macrofoam swabs was evaluated for its accuracy, precision, reproducibility, and limit of detection. Macrofoam swabs recovered 31.7 to 49.1% of spores from 10-cm2 steel surfaces with a < or =32.7% coefficient of variation in sampling precision and reproducibility for inocula of > or =38 spores.
References
-
- Baldock, J. D. 1974. Microbiologic monitoring of the food plant: methods to assess bacterial contamination on surfaces. J. Milk Food Technol. 37:361-368.
-
- Dewan, P. K., A. M. Fry, K. Laserson, B. C. Tierney, C. P. Quinn, J. A. Hayslett, L. N. Broyles, A. Shane, K. L. Winthrop, I. Walks, L. Siegel, T. Hales, V. A. Semenova, S. Romero-Steiner, C. Elie, R. Khabbaz, A. S. Khan, R. A. Hajjeh, A. Schuchat, et al. 2002. Inhalational anthrax outbreak among postal workers, Washington, D.C., 2001. Emerg. Infect. Dis. 8:1066-1072. - PMC - PubMed
-
- Favero, M. S. 1968. Microbiological sampling of surfaces. J. Appl. Bacteriol. 31:336-343. - PubMed
-
- Favero, M. S. 1971. Microbiologic assay of space hardware. Environ. Biol. Med. 1:27-36. - PubMed