Ultrasound imaging and contrast agents: a safe alternative to MRI?
- PMID: 16754192
- DOI: 10.1080/13645700600674252
Ultrasound imaging and contrast agents: a safe alternative to MRI?
Abstract
Microbubble contrast media are used to enhance ultrasound images. Because ultrasound is a real-time investigation, contrast-enhanced ultrasound offers possibilities for perfusion imaging. This review is conducted to evaluate the safety of contrast-enhanced ultrasound and its possible role in medical imaging. The safety of diagnostic ultrasound is still an important field of research. The wanted and unwanted effects of ultrasound and microbubble contrast media as well as the effects of ultrasound on these microbubbles are described. Furthermore, some of the possible applications and indications of contrast-enhanced ultrasound will be discussed. The shared advantages of MRI and ultrasound are the use of non-ionizing radiation and non-nephrotoxic contrast media. From this review it can be concluded that, for certain indications, contrast enhanced ultrasound could be a safe alternative to MRI and a valuable addition to medical imaging.
Similar articles
-
Superparamagnetic iron oxide nanoparticle-embedded encapsulated microbubbles as dual contrast agents of magnetic resonance and ultrasound imaging.Biomaterials. 2009 Aug;30(23-24):3882-90. doi: 10.1016/j.biomaterials.2009.03.051. Epub 2009 Apr 22. Biomaterials. 2009. PMID: 19395082
-
Therapeutic use of ultrasound targeted microbubble destruction: a review of non-cardiac applications.Ultraschall Med. 2006 Apr;27(2):134-40. doi: 10.1055/s-2005-858993. Ultraschall Med. 2006. PMID: 16612722 Review.
-
Ultrasound contrast agents: an overview.Eur J Radiol. 2006 Dec;60(3):324-30. doi: 10.1016/j.ejrad.2006.06.022. Epub 2006 Aug 30. Eur J Radiol. 2006. PMID: 16938418 Review.
-
Microbubble contrast for radiological imaging: 1. Principles.Ultrasound Q. 2006 Mar;22(1):5-13. Ultrasound Q. 2006. PMID: 16641788 Review.
-
[Recent progress of the medical ultrasound contrast imaging technology].Nihon Rinsho. 1998 Apr;56(4):854-9. Nihon Rinsho. 1998. PMID: 9577597 Review. Japanese.
Cited by
-
Imaging of Abdominal Aortic Aneurysm: the present and the future.Curr Vasc Pharmacol. 2010 Nov;8(6):808-19. doi: 10.2174/157016110793563898. Curr Vasc Pharmacol. 2010. PMID: 20180767 Free PMC article. Review.
-
Molecular imaging of experimental abdominal aortic aneurysms.ScientificWorldJournal. 2013 Apr 23;2013:973150. doi: 10.1155/2013/973150. Print 2013. ScientificWorldJournal. 2013. PMID: 23737735 Free PMC article. Review.
-
Diagnostic performance of contrast-enhanced ultrasonography for predicting therapeutic response to radiofrequency ablation in patients with hepatocellular carcinoma: a meta-analysis.Discov Oncol. 2025 Jul 1;16(1):1237. doi: 10.1007/s12672-025-03008-x. Discov Oncol. 2025. PMID: 40591162 Free PMC article.
-
Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney.Arch Med Sci. 2013 Aug 30;9(4):608-13. doi: 10.5114/aoms.2013.37271. Epub 2013 Aug 29. Arch Med Sci. 2013. PMID: 24049518 Free PMC article.
-
Applications of magnetic microbubbles for theranostics.Theranostics. 2012;2(1):103-12. doi: 10.7150/thno.3464. Epub 2012 Jan 12. Theranostics. 2012. PMID: 22287990 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical