Comparative Study
. 1975 Jul;30(1):58-65.
doi: 10.1128/am.30.1.58-65.1975.

Comparative study of four microporous filters for concentrating viruses from drinking water

Comparative Study

Comparative study of four microporous filters for concentrating viruses from drinking water

W Jakubowski et al. Appl Microbiol. 1975 Jul.

Abstract

Four microporous virus-absorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston greater than Cox 267-mm greater than MF 293-mm congruent to K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-mum porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory.

PubMed Disclaimer