Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2006 Oct;15(4):273-8.
doi: 10.1016/j.ijoa.2006.03.004. Epub 2006 Jun 13.

Ultra-low dose combined spinal-epidural anesthesia with intrathecal bupivacaine 3.75 mg for cesarean delivery: a randomized controlled trial

Affiliations
Randomized Controlled Trial

Ultra-low dose combined spinal-epidural anesthesia with intrathecal bupivacaine 3.75 mg for cesarean delivery: a randomized controlled trial

W H L Teoh et al. Int J Obstet Anesth. 2006 Oct.

Abstract

Background: We wished to investigate the feasibility of an ultra low-dose combined spinal-epidural technique in providing surgical anesthesia for uncomplicated cesarean deliveries in a randomized, double-blind controlled trial.

Method: Forty-four normotensive, non-obese patients were randomized to receive either intrathecal hyperbaric bupivacaine 3.75 mg (low dose group, n=22) or 9 mg (conventional group, n=22), in addition to intrathecal fentanyl 25 microg, morphine 100 microg, and epidural 1.5% lidocaine 3 mL. Sensorimotor anesthesia and hemodynamic data were assessed at 2.5-min intervals for the first 15 min.

Results: The maximal sensory block achieved in the low-dose group was significantly lower than that in the conventional group (median T3, [range T2-T6] vs. T2 [C2-T6], P<0.001) with a longer time taken to reach maximal sensory block. The low-dose group had less motor block, faster sensory regression to T10 dermatome and faster motor recovery to Bromage 0 (all P<0.001). The block failed to reach T6 bilaterally within 10 min in one patient in the low-dose group and two in the conventional group, with no significant difference in the need for epidural supplementation before or after delivery of the baby. The low-dose group experienced less hypotension (14% vs. 73%, P<0.001) with less ephedrine usage (0.68 vs. 17.5 mg, P<0.001). There was no difference in operating conditions and other side effects (shivering, pruritus).

Conclusion: We conclude that this technique results in a significantly lower incidence of maternal hypotension and has a role in high-risk parturients in whom maintenance of stable hemodynamics is imperative.

PubMed Disclaimer

Comment in

Publication types