Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jun 20;47(12):2493-7.
doi: 10.1016/j.jacc.2006.02.049. Epub 2006 May 30.

The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators

Affiliations

The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators

Matthew R Reynolds et al. J Am Coll Cardiol. .

Abstract

Objectives: We aimed to quantify the frequency and nature of early complications after implantable cardioverter-defibrillator (ICD) implantation in general practice, and estimate the incremental costs of those complications to the health care system.

Background: Cardioverter-defibrillator implantation rates are rising quickly. Little has been published regarding the outcomes and costs of these procedures in unselected populations.

Methods: Using Medicare Provider Analysis and Review (MedPAR) files, we identified 30,984 admissions containing procedure codes for new ICD or cardiac resynchronization therapy defibrillator implantation in fiscal year 2003. The frequencies of eight complicating diagnoses during these admissions were determined. Length of stay (LOS) and total hospital costs, derived using whole-hospital cost to charge ratios, were calculated for each admission. The incremental effects of any and each complication on LOS and hospital cost were estimated in multivariable models, adjusting for demographic factors and comorbid conditions.

Results: The mean cost for all admissions was 42,184 dollars (median 37,902 dollars) with mean LOS of 4.7 days (median 2.0 days). One or more complications were coded in 10.8% of admissions, most commonly "mechanical complication of the ICD" and hemorrhage/hematoma. The occurrence of any complication increased adjusted LOS by 3.4 days and costs by 7,251 dollars. Each of the individual complications was associated with highly significant increases in both LOS (1 to 10 days) and hospital cost (5,000 dollars to 20,000 dollars).

Conclusions: In fiscal 2003, 10.8% of Medicare patients undergoing cardioverter-defibrillator implantation experienced one or more early complications, associated with significant increases in LOS and costs. Efforts to reduce these complications could have significant clinical and financial benefits.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Frequency distribution of the number of complications for the entire study population.
Figure 2
Figure 2
Observed and adjusted average hospital cost for patients with (solid bars) and without complications (open bars).

References

    1. Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352:225–37. - PubMed
    1. Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346:877–83. - PubMed
    1. Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004;350:2151–8. - PubMed
    1. McClellan MB, Tunis SR. Medicare coverage of ICDs. N Engl J Med. 2005;352:222–4. - PubMed
    1. Reynolds MR, Josephson ME. MADIT II (second Multicenter Automated Defibrillator Implantation Trial) debate: risk stratification, costs, and public policy. Circulation. 2003;108:1779–83. - PubMed