Constrained liners in revision total hip arthroplasty: an overuse syndrome: in the affirmative
- PMID: 16781444
- DOI: 10.1016/j.arth.2006.02.100
Constrained liners in revision total hip arthroplasty: an overuse syndrome: in the affirmative
Abstract
Instability after primary and revision total hip arthroplasty continues to be problematic for the surgeon. The use of constrained liners, which use a locking mechanism to capture the femoral head, has increased to help manage this problem. Constrained liners, however, present problems with acetabular component loosening, dissociation of the liner/shell interface, failure by breakage, and excessive polyethylene wear. Rather than resort to constrained liners, our approach has been to restore joint stability with large-diameter femoral heads. The advantages are increased range of motion due to more favorable head/neck ratio, increased resistance to dislocation due to increased jump distance, and the avoidance of skirted femoral heads. With the addition of cross-linked polyethylene, the volumetric wear associated with large heads is much decreased and makes this a viable option today.
Comment in
-
Constrained liners in revision: total hip arthroplasty an overuse syndrome: in opposition.J Arthroplasty. 2006 Jun;21(4 Suppl 1):126-30. doi: 10.1016/j.arth.2006.01.027. J Arthroplasty. 2006. PMID: 16781445
Similar articles
-
Constrained liners in revision: total hip arthroplasty an overuse syndrome: in opposition.J Arthroplasty. 2006 Jun;21(4 Suppl 1):126-30. doi: 10.1016/j.arth.2006.01.027. J Arthroplasty. 2006. PMID: 16781445
-
Have large femoral heads reduced prosthetic impingement in total hip arthroplasty?Hip Int. 2019 Jan;29(1):83-88. doi: 10.1177/1120700018761153. Epub 2018 May 7. Hip Int. 2019. PMID: 29734855
-
Constrained Acetabular Liners.J Arthroplasty. 2018 May;33(5):1331-1336. doi: 10.1016/j.arth.2018.01.026. Epub 2018 Mar 7. J Arthroplasty. 2018. PMID: 29525341
-
Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results.Clin Orthop Relat Res. 2006 Jun;447:53-9. doi: 10.1097/01.blo.0000218742.61624.80. Clin Orthop Relat Res. 2006. PMID: 16741475
-
Instability after total hip arthroplasty: treatment with large femoral heads vs constrained liners.J Arthroplasty. 2008 Oct;23(7 Suppl):59-63. doi: 10.1016/j.arth.2008.06.032. J Arthroplasty. 2008. PMID: 18922375 Review.
Cited by
-
Removing Cemented Dual Mobility Liners From Acetabular Components: A Technical Tip for a Challenging Surgical Problem.Arthroplast Today. 2023 Sep 21;23:101211. doi: 10.1016/j.artd.2023.101211. eCollection 2023 Oct. Arthroplast Today. 2023. PMID: 37781023 Free PMC article.
-
Postoperative radiograph of the hip arthroplasty: what the radiologist should know.Insights Imaging. 2015 Dec;6(6):591-600. doi: 10.1007/s13244-015-0438-5. Epub 2015 Oct 20. Insights Imaging. 2015. PMID: 26487647 Free PMC article.
-
Post-traumatic Total Hip Arthroplasty After Acetabular Fractures: Benefits of the Hardinge Approach.Cureus. 2024 Jun 30;16(6):e63537. doi: 10.7759/cureus.63537. eCollection 2024 Jun. Cureus. 2024. PMID: 39086790 Free PMC article.
-
Impact of Acetabular Implant Design on Aseptic Failure in Total Hip Arthroplasty.Arthroplast Today. 2021 Jan 7;7:60-68. doi: 10.1016/j.artd.2020.11.017. eCollection 2021 Feb. Arthroplast Today. 2021. PMID: 33521199 Free PMC article.
-
Dual Mobility in Total Hip Arthroplasty: Biomechanics, Indications and Complications-Current Concepts.Indian J Orthop. 2021 Oct 13;55(5):1202-1207. doi: 10.1007/s43465-021-00471-w. eCollection 2021 Oct. Indian J Orthop. 2021. PMID: 34824721 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical