Dry beveling micropipettes using a computer hard drive
- PMID: 16782203
- DOI: 10.1016/j.jneumeth.2006.05.009
Dry beveling micropipettes using a computer hard drive
Abstract
It is sometimes useful in electrophysiological recordings to try various micropipette profiles in order to determine which tip works best in a given experiment. A pipette puller can be used to pull very sharp or blunt pipettes, and to fire polish tips for whole cell patch recordings. Broken tip pipettes can be "bumped" to an acceptable tip diameter under a microscope. However, it may be difficult to rationalize the purchase of a commercial beveling machine simply to test whether beveled pipettes are best for recording intracellularly from the cell types of interest. Presented here are methods that use a surplus computer hard drive to reproducibly dry bevel glass micropipettes. Compared to sharp or broken tip electrodes, pipettes dry beveled with this simple system are superior for making intracellular recordings from cichlid Mauthner neurons. Preliminary data obtained with this inexpensive apparatus may allow investigators to successfully justify the purchase of a commercial beveler.
Similar articles
-
Pressure polishing: a method for re-shaping patch pipettes during fire polishing.J Neurosci Methods. 2000 Jul 31;100(1-2):13-5. doi: 10.1016/s0165-0270(00)00224-7. J Neurosci Methods. 2000. PMID: 11040361
-
A multimicroelectrode system composed of independent glass micropipettes with an eccentric tip structure for simultaneous intracellular recording.IEEE Trans Biomed Eng. 1992 Jun;39(6):656-8. doi: 10.1109/10.141205. IEEE Trans Biomed Eng. 1992. PMID: 1601448
-
Making patch-pipettes and sharp electrodes with a programmable puller.J Vis Exp. 2008 Oct 8;(20):939. doi: 10.3791/939. J Vis Exp. 2008. PMID: 19078940 Free PMC article.
-
Methods for single-cell recording and labeling in vivo.J Neurosci Methods. 2019 Sep 1;325:108354. doi: 10.1016/j.jneumeth.2019.108354. Epub 2019 Jul 11. J Neurosci Methods. 2019. PMID: 31302156 Review.
-
Advanced real-time recordings of neuronal activity with tailored patch pipettes, diamond multi-electrode arrays and electrochromic voltage-sensitive dyes.Pflugers Arch. 2021 Jan;473(1):15-36. doi: 10.1007/s00424-020-02472-4. Epub 2020 Oct 13. Pflugers Arch. 2021. PMID: 33047171 Free PMC article. Review.
Cited by
-
Energetic diversity in retinal ganglion cells is modulated by neuronal activity and correlates with resilience to degeneration.Res Sq [Preprint]. 2025 Mar 12:rs.3.rs-5989609. doi: 10.21203/rs.3.rs-5989609/v1. Res Sq. 2025. PMID: 40162221 Free PMC article. Preprint.
-
An updated suite of viral vectors for in vivo calcium imaging using intracerebral and retro-orbital injections in male mice.Nat Commun. 2023 Feb 4;14(1):608. doi: 10.1038/s41467-023-36324-3. Nat Commun. 2023. PMID: 36739289 Free PMC article.
-
Robust fluorescent labelling of micropipettes for use in fluorescence microscopy: application to the observation of a mosquito borne parasite infection.J Microsc. 2018 Jan;269(1):78-84. doi: 10.1111/jmi.12610. Epub 2017 Aug 10. J Microsc. 2018. PMID: 28795398 Free PMC article.
-
High-yield in vitro recordings from neurons functionally characterized in vivo.Nat Protoc. 2018 Jun;13(6):1275-1293. doi: 10.1038/nprot.2018.026. Epub 2018 May 10. Nat Protoc. 2018. PMID: 29748648
-
Primary Myofibroblasts Maintain Short-Term Viability following Submucosal Injection in Syngeneic, Immune-Competent Mice Utilizing Murine Colonoscopy.PLoS One. 2015 May 27;10(5):e0127258. doi: 10.1371/journal.pone.0127258. eCollection 2015. PLoS One. 2015. PMID: 26016485 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources