Abstract
Objective: To study the relevant position of C(2) pedicle to C(2) inferior articular process, set up a technique of C(2) pedicle screw placement with the inferior articular process of axis as an anatomic landmark.
Methods: Fifty C(2) bone specimens were used to measure the distance from the sagittal midline to the medial border, the midpoint and the lateral border of C(2) inferior articular process or C(2) pedicle; the width and the height of the C(2) pedicle were also evaluated. The anatomic relation between the measurements data of C(2) pedicle and that of C(2) inferior articular process were analyzed, and the technique of C(2) pedicle screw fixation was established.
Results: The medial border of C(2) inferior articular process was averaged (3.67 +/- 0.41) mm lateral to that of C(2) pedicle, and the midpoint C(2) inferior articular process was averaged (1.15 +/- 0.44) mm lateral to the lateral border of C(2) pedicle, respectively. Using the C(2) inferior articular process as landmark, two techniques was established for C(2) pedicle screw placement. The entry point of method A was located in 2 mm medial and superior to the central point of C(2) inferior articular process; the entry point of method B was at the crossing point of the medial border C(2) inferior articular process with the superior quarter of C(2) inferior articular process.
Conclusions: There is a steady anatomic relation between C(2) pedicle and C(2) inferior articular process, the C(2) inferior articular process could be as a convenient key anatomic landmark to determine the location of C(2) pedicle and the position of C(2) pedicle screw entry point.
Similar articles
-
[Anatomic identification of the location of the pedicle of atlas with the lateral mass of C2 to C4 as the landmark].Zhonghua Wai Ke Za Zhi. 2005 Jun 15;43(12):774-6. Zhonghua Wai Ke Za Zhi. 2005. PMID: 16083577 Chinese.
-
[ANATOMIC STUDY ON ENTRY POINT AND IMPLANT TECHNIQUE FOR C2 PEDICLE SCREW FIXATION].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2015 Feb;29(2):175-8. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2015. PMID: 26455145 Chinese.
-
An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine.Spine (Phila Pa 1976). 2009 Jun 1;34(13):1355-62. doi: 10.1097/BRS.0b013e3181a4f3a9. Spine (Phila Pa 1976). 2009. PMID: 19478655
-
[The feasibilty study of posterior laminar screw fixation techniques in axis].Zhongguo Gu Shang. 2008 Aug;21(8):581-4. Zhongguo Gu Shang. 2008. PMID: 19108367 Chinese.
-
[Anatomic study of the posterior laminar screw fixation on C7].Zhongguo Gu Shang. 2010 Apr;23(4):282-5. Zhongguo Gu Shang. 2010. PMID: 20486381 Chinese.
Cited by
-
Evaluation of the Anatomical Reference Point in Posterior Minimally Invasive Atlantoaxial Spine Surgery: A Cadaveric Anatomical Study.Orthop Surg. 2024 Apr;16(4):943-952. doi: 10.1111/os.14023. Epub 2024 Mar 4. Orthop Surg. 2024. PMID: 38433589 Free PMC article.
-
Morphological character of cervical spine for anterior transpedicular screw fixation.Indian J Orthop. 2013 Nov;47(6):553-8. doi: 10.4103/0019-5413.121575. Indian J Orthop. 2013. PMID: 24379459 Free PMC article.
-
The effectiveness and safety of 3-dimensional printed composite guide plate for atlantoaxial pedicle screw: A retrospective study.Medicine (Baltimore). 2019 Jan;98(1):e13769. doi: 10.1097/MD.0000000000013769. Medicine (Baltimore). 2019. PMID: 30608387 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous