Comparative Study
. 2006 Jul-Aug;22(6):538-43.
doi: 10.1097/01.ajp.0000202977.98420.27.

Ultrasound-guided facet joint injections in the middle to lower cervical spine: a CT-controlled sonoanatomic study

Affiliations
Comparative Study

Ultrasound-guided facet joint injections in the middle to lower cervical spine: a CT-controlled sonoanatomic study

Klaus Galiano et al. Clin J Pain. 2006 Jul-Aug.

Abstract

Objectives: The aim of this study was to investigate the efficacy of ultrasound as a guiding tool for simulated cervical facet joint injections in cadavers.

Methods: A total of 40 ultrasound examinations at 5 levels (C6-7 to C2-3) were performed on 4 embalmed cadavers. The zygapophyseal joints were located with ultrasound. First, the transverse processes of C6 and C7 were established and the facet joint of C6-7 was demonstrated. The midpoint of this joint space, defined as the middle of its cranio-caudal extension on its lateral surface, was taken as a reference point. Ipsilateral distances (A, B, C, and D) between this point and each one of the 4 facet joints of the cervical spine up to the facet joints C2-3 were then computed. Subsequently, coronal computed tomography (CT) scans were taken to verify these distances. In a second experiment, a spinal needle was advanced under ultrasound guidance to the zygapophyseal joints from C2-3 to C6-7 on both sides of 1 cadaver. The exact placement of the needle tips was again verified by CT.

Results: In 4 attempts, a depiction of the joint space was not possible. Ultrasound and CT provided the same mean measurements of 1.2+/-0.2 cm, 2.0+/-0.3 cm, 3.0+/-0.2, and 4.0+/-0.5 cm for distances A, B, C, and D, respectively. All 10 needle tips were located in the joint space during simulated facet joint injections, as also verified by CT.

Discussion: This preclinical study suggests that ultrasound is a useful guiding tool for facet joint injections in the cervical spine.

PubMed Disclaimer