Comparison of hemodynamic profiles in transurethral resection of prostate vs transurethral resection of urinary bladder tumors during spinal anesthesia: a bioimpedance study
- PMID: 16797424
- DOI: 10.1016/j.jclinane.2005.12.008
Comparison of hemodynamic profiles in transurethral resection of prostate vs transurethral resection of urinary bladder tumors during spinal anesthesia: a bioimpedance study
Abstract
Study objective: Transurethral resection of prostate (TURP) is more frequently associated with perioperative fluid and electrolyte disturbances than transurethral resection of bladder tumors (TURT) because of irrigating fluid absorption. Because fluid overload may cause hypertension, we compared the patients' intraoperative hemodynamic profiles (including the incidence of hypertension) during TURP vs TURT, both performed during spinal anesthesia, by using the bioimpedance method.
Design: Prospective single-blind study.
Setting: University hospital.
Patients: 80 (40 in each group) men, ASA physical status I and II.
Interventions: Patients underwent TURP or TURT surgery with spinal anesthesia.
Measurements: Mean arterial pressure, heart rate, cardiac index, and systemic vascular resistance were compared between the 2 groups. A mean arterial pressure greater than 30% from the baseline value was considered as hypertension. Plasma sodium was measured preoperatively, intraoperatively, and postoperatively.
Main results: Transurethral resection of prostate patients received more irrigating fluid (7900 +/- 2310 vs 5650 +/- 21560, P < 0.05) and had a higher calculated volume of fluid absorbed: 638 +/- 60 vs 303 +/- 40 mL for the TURT patients (P < 0.05). Mean arterial pressures were higher with TURP, 30 minutes after the onset of surgery and at the end of the procedure (111 +/- 15 vs 100 +/- 10 and 109 +/- 14 vs 99 +/- 14 mmHg, respectively; P < 0.05). However, there was no hypertension in either group. There were no differences in hemodynamic measurements of hyponatremic vs normonatremic patients. Plasma sodium decreased postoperatively more in the TURP group (140.4 +/- 2.6 mEq/L baseline to 134.1 +/- 3.5 mEq/L, P < 0.05) and was lower postoperatively in the TURP group compared with TURT (134.1 +/- 3.5 vs 137.2 +/- 2.9 mEq/L, P = 0.04).
Conclusions: Although more irrigating fluid was absorbed in the TURP group, there were no episodes of hypertension in either group.
Similar articles
-
The effect of the choice of irrigation fluid on cardiac stress during transurethral resection of the prostate: a comparison between 1.5% glycine and 5% glucose.J Urol. 2007 Apr;177(4):1369-73. doi: 10.1016/j.juro.2006.11.042. J Urol. 2007. PMID: 17382734 Clinical Trial.
-
A prospective, randomized trial comparing conventional transurethral prostate resection with PlasmaKinetic vaporization of the prostate: physiological changes, early complications and long-term followup.J Urol. 2006 Jul;176(1):205-9. doi: 10.1016/S0022-5347(06)00492-7. J Urol. 2006. PMID: 16753403 Clinical Trial.
-
Glucose as a marker of fluid absorption in bipolar transurethral surgery.Anesth Analg. 2009 Dec;109(6):1850-5. doi: 10.1213/ane.0b013e3181b0843b. Anesth Analg. 2009. PMID: 19923514 Clinical Trial.
-
The use of ethanol as a marker to detect and quantify the absorption of irrigation fluid during transurethral resection of the prostate.Scand J Urol Nephrol Suppl. 1996;178:1-64. Scand J Urol Nephrol Suppl. 1996. PMID: 8837259 Review.
-
[Reabsorption syndrome. Report of a case].Arch Esp Urol. 2001 May;54(4):378-80. Arch Esp Urol. 2001. PMID: 11455777 Review. Spanish.
Cited by
-
Usefulness of non-invasive cardiac output monitoring in elderly patients undergoing monopolar transurethral resection of the prostate: a pilot study.J Int Med Res. 2020 May;48(5):300060520922422. doi: 10.1177/0300060520922422. J Int Med Res. 2020. PMID: 32368951 Free PMC article.
-
A rare complication of transurethral resection: Transient Blindness.Ulus Travma Acil Cerrahi Derg. 2024 Jan;30(12):921-924. doi: 10.14744/tjtes.2024.33979. Ulus Travma Acil Cerrahi Derg. 2024. PMID: 39668538 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical