Development of restricted-access media supports and their application to the direct analysis of biological fluid samples via high-performance liquid chromatography
- PMID: 16800052
- DOI: 10.1007/s00216-005-0253-9
Development of restricted-access media supports and their application to the direct analysis of biological fluid samples via high-performance liquid chromatography
Erratum in
- Anal Bioanal Chem. 2006 Aug;385(8):1580
Abstract
A quick overview of published methods for analyzing compounds in complex biological samples reveals that the most difficult step is the clean-up or extraction of a required compound from the matrix. The strategy required to analyze exogenous compounds in biological fluids depends greatly upon the nature of the compound and upon the biomatrix. Coupled-column separation using restricted-access media as the first dimension in order to exclude macromolecules and retain micromolecules has been successfully used for a number of biological fluids. This paper presents the history of the development of restricted-access media supports and of their application to the direct injection of biological fluid samples in high-performance liquid chromatography.
Similar articles
-
Alkyl diol silica: restricted access pre-column packings for fast liquid chromatography-integrated sample preparation of biological fluids.J Chromatogr A. 2001 Feb 9;909(1):73-8. doi: 10.1016/s0021-9673(00)01175-4. J Chromatogr A. 2001. PMID: 11218143
-
A method for determination of the plasma levels of modafinil enantiomers, (+/-)-modafinic acid and modafinil sulphone by direct human plasma injection and bidimensional achiral-chiral chromatography.J Pharm Biomed Anal. 2008 Apr 14;46(5):937-44. doi: 10.1016/j.jpba.2007.03.004. Epub 2007 Mar 13. J Pharm Biomed Anal. 2008. PMID: 17478071
-
An automated method of sample preparation of biofluids using pierceable caps to eliminate the uncapping of the sample tubes during sample transfer.J Biochem Biophys Methods. 2000 Sep 11;45(2):193-204. doi: 10.1016/s0165-022x(00)00117-2. J Biochem Biophys Methods. 2000. PMID: 10989135
-
Restricted-access media supports for direct high-throughput analysis of biological fluid samples: review of recent applications.Bioanalysis. 2009 Jun;1(3):577-94. doi: 10.4155/bio.09.39. Bioanalysis. 2009. PMID: 21083154 Review.
-
Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis.J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Mar 5;801(2):141-56. doi: 10.1016/j.jchromb.2003.11.043. J Chromatogr B Analyt Technol Biomed Life Sci. 2004. PMID: 14751782 Review.
Cited by
-
Magnetic/Zeolitic Imidazolate Framework-67 Nanocomposite for Magnetic Solid-Phase Extraction of Five Flavonoid Components from Chinese Herb Dicranopteris pedata.Molecules. 2023 Jan 10;28(2):702. doi: 10.3390/molecules28020702. Molecules. 2023. PMID: 36677760 Free PMC article.
-
Detection and quantification of Covid-19 antiviral drugs in biological fluids and tissues.Talanta. 2021 Mar 1;224:121862. doi: 10.1016/j.talanta.2020.121862. Epub 2020 Nov 5. Talanta. 2021. PMID: 33379073 Free PMC article. Review.
-
Applications of chromatographic methods in metabolomics: A review.J Chromatogr B Analyt Technol Biomed Life Sci. 2024 May 15;1239:124124. doi: 10.1016/j.jchromb.2024.124124. Epub 2024 Apr 16. J Chromatogr B Analyt Technol Biomed Life Sci. 2024. PMID: 38640794 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources