Is there a role of statins in the prevention of aortic biological prostheses degeneration
- PMID: 16805917
- PMCID: PMC1550427
- DOI: 10.1186/1476-7120-4-26
Is there a role of statins in the prevention of aortic biological prostheses degeneration
Abstract
It has been recently observed that statins might slow the progression of aortic stenosis or sclerosis. Preliminary reports suggested a similar positive effect in reducing the degeneration of aortic valve bioprostheses even though this hypothesis should be further proven and supported by new data. In this review the present evidences of the possible effects of statins in this field are discussed.
Figures
Similar articles
-
[Transcatheter aortic valve implantation for degeneration of biological aortic prosthesis].Kardiol Pol. 2012;70(12):1277-9. Kardiol Pol. 2012. PMID: 23264247 Polish.
-
Degeneration of native and tissue prosthetic valve in aortic position: do statins play an effective role in prevention?Int J Cardiol. 2007 Mar 20;116(2):144-52. doi: 10.1016/j.ijcard.2006.03.047. Epub 2006 Jul 10. Int J Cardiol. 2007. PMID: 16828903 Review.
-
Do statins slow the process of calcification of aortic tissue valves?Interact Cardiovasc Thorac Surg. 2010 Sep;11(3):297-301. doi: 10.1510/icvts.2009.230920. Epub 2010 Jun 22. Interact Cardiovasc Thorac Surg. 2010. PMID: 20570976 Review.
-
Effect of statins on the progression of bioprosthetic aortic valve degeneration.Am J Cardiol. 2003 Dec 15;92(12):1479-82. doi: 10.1016/j.amjcard.2003.08.066. Am J Cardiol. 2003. PMID: 14675593
-
Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses CoreValve for failed bioprosthetic aortic valve replacements.J Am Coll Cardiol. 2010 Jan 12;55(2):97-101. doi: 10.1016/j.jacc.2009.06.060. J Am Coll Cardiol. 2010. PMID: 20117377
Cited by
-
Can statins improve outcomes after isolated cardiac valve surgery? A systematic literature review.Clin Cardiol. 2013 Aug;36(8):448-55. doi: 10.1002/clc.22140. Epub 2013 May 13. Clin Cardiol. 2013. PMID: 23670956 Free PMC article.
References
-
- Bloomfield P, Wheatley DJ, Prescott RJ, Miller HC. Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprosthesis. N Engl J Med. 1991;324:573–579. - PubMed
-
- Hammermeister K, Sethi GK, Henderson WG, Grover FL, Oprian C, Rahimtoola S. Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs Randomized Trial. J Am Coll Cardiol. 2000;36:1152–1158. doi: 10.1016/S0735-1097(00)00834-2. - DOI - PubMed
-
- UK Heart Valve Registry. London: Imperial College School of Medicine, Hammersmith Hospital; 1999. The United Kingdom Heart Valve Registry Report 1997.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical