Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2006 Nov;28(5):910-4.
doi: 10.1183/09031936.06.00124905. Epub 2006 Jun 28.

Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically normal mediastinum

Affiliations
Free article
Clinical Trial

Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically normal mediastinum

F J F Herth et al. Eur Respir J. 2006 Nov.
Free article

Abstract

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) can sample enlarged mediastinal lymph nodes in patients with nonsmall cell lung cancer (NSCLC). To date, EBUS-TBNA has only been used to sample nodes visible on computed tomography (CT). The aim of the present study was to determine the accuracy of EBUS-TBNA in sampling nodes <or=1 cm in diameter. NSCLC patients with CT scans showing no enlarged lymph nodes (no node >1 cm) in the mediastinum underwent EBUS-TBNA. Identifiable lymph nodes at locations 2r, 2l, 4r, 4l, 7, 10r, 10l, 11r and 11l were aspirated. All patients underwent subsequent surgical staging. Diagnoses based on aspiration results were compared with those based on surgical results. In 100 patients (mean age 58.9 yrs; 68 males), 119 lymph nodes ranging 5-10 mm in size were detected and sampled. Malignancy was detected in 19 patients but missed in two; all diagnoses were confirmed by surgical findings. The mean diameter of the punctured lymph nodes was 8.1 mm. The sensitivity of EBUS-TBNA for detecting malignancy was 92.3%, specificity was 100%, and the negative predictive value was 96.3%. No complications occurred. In conclusion, endobronchial ultrasound-guided transbronchial needle aspiration can accurately sample even small mediastinal nodes, therefore avoiding unnecessary surgical exploration in one out of six patients who have no computed tomography evidence of mediastinal disease. Potentially operable patients with no signs of mediastinal involvement on computed tomography may benefit from pre-surgical endobronchial ultrasound-guided transbronchial needle aspiration and staging.

PubMed Disclaimer

LinkOut - more resources